11. Soft Switch
MODE
1
Bit:
786
Bit
7
RTN sending criteria based
on continuous error line
detection (Standard)
6
5
4
3
2
1
0
MODE
1
Bit:
787
Bit
7
RTN sending criteria based
on continuous error line
detection (Fine)
6
5
4
3
2
1
0
180
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
0 1 1 0
Feature
0
Bit 7-0:
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
1 1 0 0
Feature
0
Bit 7-0:
Field Service Ver. 2.5 Jul. 2006
HEX: 00 (For U.S.)
HEX: 06 (For Europe)
Logic
1
00000000 Use of con-
ventional
threshold
00000001 1 Line
00000110 6 Line
|
01100100 100 Line
Others
Not available
HEX: 00 (For U.S.)
HEX: 0C (For Europe)
Logic
1
00000000 Use of con-
ventional
threshold
00000001 1 Line
00001100 12 Line
|
01100100 100 Line
Others
Not available
Description
Set RTN sending crite-
ria (Standard) based
continuous error line
detection. If setting the
conventional thresh-
old, use the one of
RTN sending error rate
at mode 044. Default is
6 lines at DTS.
Description
Set RTN sending crite-
ria (Fine) based contin-
uous error line
detection. If setting the
conventional threshold,
use the one of RTN
sending error rate at
mode 044. Default is
12 lines at DTS.