Field Service Ver. 2.5 Jul. 2006
6.4
Cleaning procedure
NOTE
• The alcohol described in the cleaning procedure represents the isopropyl alcohol.
6.4.1
Manual Bypass Feed Roller
1. Remove the Manual Bypass Unit.
See P.70
[1]
[3]
6.4.2
Manual Bypass Separation Roller
1. Remove the Manual Bypass Unit.
See P.70
[1]
[3]
[2]
4037F2C515DA
4037F2C516DA
[2]
4037F2C515DA
4037F2C521DA
2. Remove two screws [1] and the Man-
ual Bypass Separation Fixing
Bracket Assy [2].
3. Using a soft cloth dampened with
alcohol, wipe the Manual Bypass
Feed Roller [3] clean of dirt.
2. Remove two screws [1] and the Man-
ual Bypass Separation Fixing
Bracket Assy [2].
3. Using a soft cloth dampened with
alcohol, wipe the Manual Bypass
Separation Roller [3] clean of dirt.
6. Other
93