Konica Minolta bizhub 200 Service Manual page 553

Hide thumbs Also See for bizhub 200:
Table of Contents

Advertisement

11. Soft Switch
MODE
1
Bit:
780
Bit
7
T4 timer after detection of
T.30 signal at manual RX
6
T5 timer
5
4
3
Confirmed time of ringing
OFF detection
MODE
1
Bit:
781
Bit
7
Interval between line block -
dial calling
6
5
4
3
2
1
0
178
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 1
0 0 0 0
Feature
0
3.0sec ±
15%
Bit 6-4:
300msec
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
0 0 1 1
Feature
0
Bit 7-0:
Field Service Ver. 2.5 Jul. 2006
HEX: 50 (For U.S.)
HEX: 10 (For Europe)
Logic
1
4.5sec ±
15%
000
Not available Set T5 timer.
001
1 minute
|
101
5 minute
|
111
7 minute
200msec Set the time to confirm the ringer off
detection.
HEX: 03
Logic
1
00000000 Not available Set the interval
00000001 0.5sec
|
00000011 1.5sec
|
00010101 10sec
Others
Not available
Description
Description
between line block and
dial calling

Advertisement