Konica Minolta bizhub 200 Service Manual page 439

Hide thumbs Also See for bizhub 200:
Table of Contents

Advertisement

11. Soft Switch
MODE
Bit:
014
Bit
Feature
7
Select redialing interval
for resending document.
6
5
1
Broadcast transmission
setting confirmation win-
0
dow. <*>
NOTE
• The features with (*) are settable by users. <*>: Soft switch setting
MODE
Bit:
016
Bit
Feature
6
Use of extra telephone.
<*>
5
Mail mode: Print date &
time received <*>
4
Mail mode: Position of
print date & time received
<*>
1
RX Time Stamp: Print
date & time received <*>
0
RX Time Stamp: Position
of print date & time
received <*>
NOTE
• The features with (*) are settable by users. <*>: Soft switch setting
64
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
0 0 0 1
Logic
0
1
Bit 7-5:
000
001
010
011
100
Others
Bit 1-0:
00
01
10
11
Factory setting bit
7 6 5 4
3 2 1 0
0 1 0 0
0 0 0 0
Logic
0
1
No
Yes
No
Yes
Inside
Outside
doc.
doc.
No
Yes
Inside
Outside
doc.
doc.
Field Service Ver. 2.5 Jul. 2006
HEX:01
Description
10ïb
30 sec
60 sec
120 sec
180 sec
Not available
Not display
Confirms settings at broadcast trans-
mission
Confirms settings (single destination/all
destinations)
Not available
HEX:40
Description
This is valid only when "(MODE 016
Bit5)" sets Yes.
This is valid only when "(MODE 016
Bit1)" sets Yes.