Toshiba Tosvert VF-AS1 Instruction Manual page 276

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

[16] PID control [2/2]
Communi
Title
cation
Function
No.
PID control feedback control
 0360
signal selection
 0361
Delay filter
 0362
Proportional (P) gain
 0363
Integral (I) gain
 0364
PID deviation upper limit
 0365
PID deviation lower limit
 0366
Differential (D) gain
 0367
Process upper limit
 0368
Process lower limit
 0369
PID control waiting time
 0370
PID output upper limit
 0371
PID output lower limit
Process increasing rate (speed type
 0372
PID control)
Process decreasing rate (speed
 0373
type PID control)
*1:  For details, refer to Instruction Manual (E6581319) specified in Section 6.42. *2:  For details, refer to Instruction Manual (E6581329) specified in Section 6.42.
*3: Inverter with a model number ending with -WN1: 60.0 -WP1: 50.0
[17] Speed feedback/positioning control
Communi
Title
cation
Function
No.

0375
Number of PG input pulses
Selection of number of PG input

0376
phases

0377
PG disconnection detection
Number of RP terminal input
0378

pulses
0379
PID output dead band

Simple positioning completion
0381

range
*1:  For details, refer to Instruction Manual (E6581319) specified in Section 6.42.
*2:  For details, refer to Instruction Manual (E6581341) specified in Section 6.42.
*3:  For details, refer to Instruction Manual (E6581329) specified in Section 6.42.
Adjustment range
0:Deviation input (no feedback input)
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:Optional AI1 (differential current input)
5:Optional AI2 (voltage/current input)
6: PG feedback option
0.0~25.0
0.01~100.0
0.01~100.0
~ Hz
~ Hz
0.00~2.55
~ Hz
~ Hz
0~2400 sec.
~ Hz
~ Hz
0.1~600.0
0.1~600.0
Adjustment range
12~9999
1:Single-phase input
2:Two-phase input
3:Two-phase input (Inversion of polarity)
0:Disabled
1:Enabled (with filter)
2:Enabled (Detection of momentary power failure)
12~9999
0~100%
1~4000
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
1/1
0
Disabled
●/●
1/1
0.1
Enabled
●/●
0.01/0.01
0.10
Enabled
●/●
0.01/0.01
0.10
Enabled
●/●
0.1/0.01
*3
Enabled
●/●
0.1/0.01
*3
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
0.1/0.01
*3
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
1/1
0
Enabled
●/●
0.1/0.01
*3
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.1
10.0
Enabled
●/●
0.1/0.1
10.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
Write during
Default
setting unit
running
Speed
(Panel/Communi
setting
control
cation)
1/1
500
Disabled
-/●
1/1
2
Disabled
-/●
1/1
0
Disabled
-/●
1/1
500
Disabled
●/●
1/1
0
Enabled
●/●
1/1
100
Enabled
-/●
PM
V/f
Reference
Torque
control
control
-
*1, *2
-
*2
-
*1, *2
-
*2
-
*2
-
*2
-
*2
-
*2
-
*2
-
*2
-
*2
-
*2
*2
-
-
*2
PM
V/f
Reference
Torque
control
control
-/●
-
-
*1
-/●
-
-
*1
-/●
-
-
*1
●/●
*2
●/●
*3
-
-
-
*1