Toshiba Tosvert VF-AS1 Instruction Manual page 268

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

[4] Terminal response time setup
Communi
Title
cation
Function
No.
Input terminal 1 response time

0140
selection (F)
Input terminal 2 response time

0141
selection (R)

0142
*6
Input terminal 4 response time

0143
selection (RES)
Input terminal 5~12 response

0144
time selection
Input terminal 13~20 response

0145
time selection

0164
Input terminal selection 17(B12) 0~135 *1

0165
Input terminal selection 18(B13) 0~135 *1

0166
Input terminal selection 19(B14) 0~135 *1

0167
Input terminal selection 20(B15) 0~135 *1
Output terminal function

0168
selection 10 (R3) *5
Output terminal function

0169
selection 11 (R4) *5

0170
Base frequency 2

0171
Base frequency voltage 2
0172
Manual torque boost 2

0173
Thermal protection level 2

0174
Base frequency 3

0175
Base frequency voltage 3

0176
Manual torque boost 3

0177
Thermal protection level 3


0178
Base frequency 4

0179
Base frequency voltage 4

0180
Manual torque boost 4

0181
Thermal protection level 4
*1:  For the adjustment range, see the table on page K-43.
*2:  For the adjustment range, see the table on page K-45.
*3: Default values vary depending on the capacity.  See the table of K-48.
*4: Inverter with a model number ending with -WN1: 60.0 -WP1: 50.0
*5: Unsupported option
*6:  has no function.
Adjustment range
2~200ms
2~200ms
-
2~200ms
2~200ms
5~200ms
0~255 *2
0~255 *2
25.0~500.0 Hz
50~330V/660V
0.0~30.0%
10~100%
25.0~500.0 Hz
50~330V/660V
0.0~30.0%
10~100%
25.0~500.0 Hz
50~330V/660V
0.0~30.0%
10~100%
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
8
Disabled
●/●
1/1
8
Disabled
●/●
-
-
-
-
1/1
8
Disabled
●/●
1/1
8
Disabled
●/●
1/1
8
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
254
Disabled
●/●
1/1
254
Disabled
●/●
0.1/0.01
*4
Disabled
-
1/0.1
*3
Disabled
-
0.1/0.1
*3
Enabled
-
1/1
100
Enabled
-
0.1/0.01
*4
Disabled
-
1/0.1
*3
Disabled
-
0.1/0.1
*3
Enabled
-
1/1
100
Enabled
-
0.1/0.01
*4
Disabled
-
1/0.1
*3
Disabled
-
0.1/0.1
*3
Enabled
-
1/1
100
Enabled
-
PM
Torque
V/f
Reference
control
control
●/●
7. 2. 3
●/●
7. 2. 3
-
-
-
-
●/●
7. 2. 3
●/●
7. 2. 3
●/●
7. 2. 3
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 2
●/●
7. 2. 2
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1
-
-
6. 4. 1

Advertisement

Table of Contents
loading

Table of Contents