Toshiba Tosvert VF-AS1 Instruction Manual page 264

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

2. Basic parameter [3/4]
Communi
Title
cation
Function
No.
Motor electronic thermal

0600
protection level 1
Electronic thermal

0017
protection characteristic
selection
Current/voltage unit

0701
selection
FM terminal meter

0005
selection
FM terminal meter
0006

adjustment
AM terminal meter
0670

selection
AM terminal meter
0671

adjustment
0300
PWM carrier frequency

Auto-restart control
0301

selection
Regenerative power

0302
ride-through control
Dynamic braking

0304
selection

0308
Dynamic braking resistance 0.5~1000Ω
Allowable continuous

0309
braking resistance
*1:  For the adjustment range, see the table on page K-40.
*2: For 200V-55/75kW models and 400V-90kW to 400V-500kW models, the carrier frequency is between 2.5 and 8.0kHz inclusive.
*3: Default values vary depending on the capacity.  See the table of K-48.
*4: Default setting value is adjusted for connection of frequency meters "QS60T". (Between FM and CCA: Approx. 3.6V) (Between AM and CCA: Approx. 3.6V)
Adjustment range
10~100%
Overload
Setting Motor type
protection
0
○ (protect)
× (not stall)
1
Standard
○ (protect)
○ (stall)
Motor
2
× (not protect)
× (not stall)
3
× (not protect)
○ (stall)
4
○ (protect)
× (not stall)
5
○ (protect)
○ (stall)
VF Motor
6
× (not protect)
× (not stall)
7
× (not protect)
○ (stall)
0:%, 1:A (ampere)/V (volt)
0~76
*1
-
0~76 *1
-
1.0~16.0kHz (2.5~8.0kHz) *2
0:Disabled
1:At auto-restart after momentary stop
2:When turning ST on or off
3:1+2
4:At start-up
0:Disabled
1:Power ride-through
2:Deceleration stop during power failure
3:Synchronized deceleration/acceleration (synchronized
acceleration/deceleration signal)
4:Synchronized deceleration/acceleration (synchronized
acceleration/deceleration signal+power failure)
0:Disabled
1:Enabled (braking resistance overload detect)
2:Enabled (braking resistance overload not detect)
0.01~600.0kW
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
(Panel/Communi
setting
running
cation)
1/1
100
Enabled
OL stall
1/1
0
Enabled
1/1
0
Enabled
1/1
0
Enabled
1/1
*4
Enabled
1/1
2
Enabled
1/1
*4
Enabled
0.1/0.1
*3
Enabled
1/1
0
Disabled
1/1
0
Disabled
1/1
0
Disabled
0.1/0.1
*3
Disabled
0.01/0.01
*3
Disabled
Vector control
PM
Speed
Torque
V/f
Reference
control
control
control
●/●
●/●
●/●
5. 14
●/●
●/●
●/●
●/●
●/●
●/●
●/●
●/●
●/●
●/●
●/●
●/●
5. 17
●/●
●/●
5. 18.1
●/●
-/-
5. 18. 2
●/●
●/●
5. 19
●/●
●/●
5. 19
●/●
●/●
5. 19
5. 14
5. 14
5. 15
5. 16
5. 16
5. 16
5. 16