8.2

Monitoring the status

8.2.1 Status monitor under normal conditions

In this mode, you can monitor the operation status of the inverter.
To monitor the inverter when it is normally running, press the
on the LED display.
Setting procedure (EX.: operation at 60 Hz)
Commun
ication
No.
*1
-
FE01
FE01
*2
-
*3
-
*4
-
*5
-
*6
-
8
*7
-
-
*8
*9
-
FE00
FE06
[Note 4]
FE07
(Continued overleaf)
Key
Item displayed
operated
Standard monitor
mode
Setting monitor
MODE
mode
Status monitor mode
MODE
(Rotating direction)
Frequency
command value
Output current
Input voltage (DC
detection)
Output voltage
Torque
Regenerative
braking resistance
overload factor
(PBrOL data)
Inverter overload
factor
(OL1 data)
Motor overload
factor
Output frequency
Input terminal
information 1
Input terminal
information 2
Input terminal
information 3
Output terminal
information 1
Output terminal
information 2
twice
MODE
key
LED
display
The output frequency is displayed (during operation).

(When standard monitor display selection  is set
to  [Output frequency])
The first basic parameter "History function ()" is

displayed.
The rotating direction is displayed. (:Forward run,

:Reverse run)
The operation frequency command value is displayed.

(When =, Frequency command)
The inverter output current (load current) is displayed.

(When =, Output current)
The Inverter DC voltage (default setting: unit %) is

displayed.(When =, Input voltage) [Note 3]
The inverter output voltage (default setting: unit %) is

displayed.(When =, output voltage)
The torque is displayed.

(When = torque)
The regenerative braking resistance overload factor is
displayed.

(When =, regenerative braking resistance
overload factor)
The inverter overload factor is displayed.

(When =, inverter overload factor)
The motor overload factor (default setting: unit %) is

displayed.
(When =, Motor overload factor)

The output frequency is displayed.
The ON/OFF status of each of the control signal input
        
terminals (F, R, RES, S1, S2, S3, RR/S4) is displayed in
bits.
The ON/OFF status of each of the optional control signal
       
input terminals (LI1, LI2, LI3, LI4) is displayed in bits.
The ON/OFF status of each of the optional control signal
       
input terminals (LI5, LI6, LI7, LI8) is displayed in bits.
The ON/OFF status of each of the control signal output
   
terminals (OUT1, OUT2, FL) is displayed in bits.
The ON/OFF status of each of the optional control signal
        
output terminals (OUT3, OUT4, R1, OUT5, OUT6, R2,
R3, R4) is displayed in bits.
H-2
E6581442
and the current status is indicated
Description