[29] Communication function [1/4]
Communi
Title
cation
Function
No.
0784

0785


0786
MAC address

0787

0788

0789

0792

0793
0794

0795

Device name
0796

0797

0798

0799

Communication speed (2-wire
0800

RS485)
Parity (common to 2-wire
0801

RS485 and 4-wire RS485)
0802
Inverter number (common)

Communications time-out time
0803
(common to 2-wire RS485 and

4-wire RS485)
Communications time-out action

0804
(common to 2-wire RS485 and
4-wire RS485)
Send waiting time (2-wire

0805
RS485)
Master/slave setting for
0806
inverter-to-inverter

communications (2-wire RS485)
Protocol selection (2-wire

0807
RS485)
*1: This parameter is Read only.
*2:This function is for Etherenet communication option.(planning)
Adjustment range
Data1
0~255
Data2
0~255
Data3
0~255
Data4
0~255
Data5
0~255
Data6
0~255
Data1
0000~FFFF
Data2
0000~ FFFF
Data3
0000~ FFFF
Data4
0000~ FFFF
Data5
0000~ FFFF
Data6
0000~ FFFF
Data7
0000~ FFFF
Data8
0000~ FFFF
0:9600 bps
1:19200 bps
2:38400 bps
0:Non parity
1:Even parity,
2:Odd parity
0~247
0:OFF, 1~100 sec.
0~8
0.00:Default, 0.01~2.00 sec.
0:Slave (issues a 0Hz command if something
goes wrong with the master)
1:Slave (continues operation if something goes
wrong with the master)
2:Slave (trips for emergency stop if something
goes wrong with the master)
3:Master (sends a frequency command)
4:Master (sends an output frequency)
5.Master (sends a torque command)
6.Master (sends an output torque command)
0:TOSHIBA
1:MODBUS
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
0
*1
●/●
1/1
1
Enabled
●/●
1/1
1
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
8
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
PM
V/f Constant Reference
Torque
control
control
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
6. 39. 1
●/●
6. 39. 1
●/●
6. 39. 1
●/●
6. 39. 1
●/●
6. 39. 1
●/●
6. 39. 1
●/●
6. 39. 1
●/●
6. 39. 1

Advertisement

Table of Contents
loading

Table of Contents