[14] Functions for lift [2/2]
Communi
Title
cation
Function
No.
0348
Braking time learning function
Acceleration/deceleration
0349
suspend function
0350
Acceleration suspend frequency 0.0~ Hz
0351
Acceleration suspend time
0352
Deceleration suspend frequency 0.0~ Hz
0353
Deceleration suspend time
[15] Commercial/inverter switching function
Communi
Title
cation
Function
No.
Commercial power/inverter
0354
switching output selection
Commercial power/inverter
0355
switching frequency
Inverter-side switching waiting
0356
time
Commercial power-side
0357
switching waiting time
Commercial power switching
0358
frequency holding time
*1: Default values vary depending on the capacity. See the table of K-48. *2: Inverter with a model number ending with -WN1: 60.0 -WP1: 50.0
[16] PID control [1/2]
Communi
Title
cation
Function
No.
0359
PID control switching
*1: For details, refer to Instruction Manual (E6581319) specified in Section 6.42. *2: For details, refer to Instruction Manual (E6581329) specified in Section 6.42.
Adjustment range
0:Disabled
1:Brake signal learning (0 after adjustment)
0:Disabled, 1:Parameter setting, 2:Terminal input
0.0~10.0 sec.
0.0~10.0 sec.
Adjustment range
0:Disabled
1:Automatic switching in the event of a trip
2:Commercial power switching frequency setting
3:Commercial power switching frequency setting +
automatic switching in the event of a trip
0~ Hz
0.10~10.00 sec.
0.40~10.00 sec.
0.10~10.00 sec.
Adjustment range
0:No PID control
1:Process type PID control (temp./pressure, etc.)
operation
2:Speed type PID control (potentiometer, etc.)
operation
3:Stop retaining P control
4.Dancer control
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
0.1/0.01
*2
Enabled
●/●
0.01/0.01
*1
Enabled
●/●
0.01/0.01
0.62
Enabled
●/●
0.01/0.01
2.00
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
Default
Write during
setting unit
Speed
setting
running
(Panel/Communi
control
cation)
1/1
0
Disabled
●/●
PM
V/f
Reference
Torque
control
control
-
-
-
6. 17
-
●
●
6. 18
-
●
●
6. 18
-
●
●
6. 18
-
●
●
6. 18
-
●
●
6. 18
PM
Torque
V/f
Reference
control
control
●/●
●
●
6. 19
●/●
●
●
6. 19
●/●
●
●
6. 19
●/●
●
●
6. 19
●/●
●
●
6. 19
PM
V/f
Reference
Torque
control
control
-
●
●
*1, *2