6.16
Light-load high-speed operation function
: Light-load high-speed operation
selection
: Light-load high-speed learning
function
: Automatic light-load high-speed
operation frequency
: Light-load high-speed operation
switching lower limit frequency
: Light-load high-speed operation
load waiting time
: Light-load high-speed operation
load detection time
: Light-load high-speed operation
heavy load detection time
For details, refer to Instruction Manual (E6581327) specified in Section 6.42.
6. 17
Braking function
: Creeping time 1
: Braking mode selection
: Load portion torque input
selection
: Hoisting torque bias input
• Function
These parameters can be used as brake sequences for lifts and similar equipment.
To ensure smooth operation, the motor produces enough torque before the brake is released.
Title
Creeping time 1
Braking mode selection
Load portion torque input
selection
Hoisting torque bias input (valid
only when =)
Lowering torque bias multiplier
Brake release time
Creeping frequency
Creeping time2
Braking time learning function
Function
~ sec.
:Disabled
:Forward winding up
:Reverse winding up
:Horizontal operation
:Disabled
:VI/II (voltage/current input)
:RR/S4 (potentiometer/voltage input)
:RX (voltage input)
: enabled
:2-wire RS485 input enabled
:4-wire RS485 input enabled
:Communications option input enabled
:Optional AI1 (differential current input)
-~ %
~ %
~ sec.
~ Hz
~ sec.
:Disabled
:Brake signal learning (0 after adjustment)
F-29
: Switching load torque during
power running
: Heavy-load torque during power
running
: Heavy-load torque during
constant-speed power running
: Switching load torque during
regenerative braking
: Lowering torque bias multiplier
: Brake release time
: Creeping frequency
: Creeping time 2
: Braking time learning function
Adjustment range
E6581442
6
Default setting