[30] My function [3/5]
Communi
Title
cation
Function
No.
0915
Input function command 33


0916
Input function target 33
Output function assigned object

0917
3

0918
My output percent data 1

0919
My output percent data 2

0920
My output percent data 3

0921
My output percent data 4

0922
My output percent data 5

0923
My output frequency data 1
0924
My output frequency data 2

0925
My output frequency data 3

0926
My output frequency data 4

0927
My output frequency data 5

0928
My output time data 1


0929
My output time data 2

0930
My output time data 3

0931
My output time data 4

0932
My output time data 5

0933
No. of times of My output data 1 0~9999 times

0934
No. of times of My output data 2 0~9999 times

0935
Input function target 41
0936
Input function command 42

0937
Input function target 42

0938
Input function command 43

0939
Input function target 43

Output function assigned object
0940

4
0941
Input function target 51

0942
Input function command 52


0943
Input function target 52

0944
Input function command 53

0945
Input function target 53
Output function assigned object

0946
5

0947
Output function target 61
*1:  For details refer to the Instruction Manual (E6581335) for this parameter.
Adjustment range
Same as 
Same as 
Same as 
0.00~200.0%
0.00~200.0%
0.00~200.0%
0.00~200.0%
0.00~200.0%
0.0~500.0Hz
0.0~500.0Hz
0.0~500.0Hz
0.0~500.0Hz
0.0~500.0Hz
0.01~600.0sec
0.01~600.0sec
0.01~600.0sec
0.01~600.0sec
0.01~600.0sec
Same as 
Same as 
Same as 
Same as 
Same as 
Same as 
Same as 
Same as 
Same as 
Same as 
Same as 
Same as 
Same as 
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
0.01/0.01
0.00
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
0.01/0.01
0.01
Enabled
●/●
0.01/0.01
0.01
Enabled
●/●
0.01/0.01
0.01
Enabled
●/●
0.01/0.01
0.01
Enabled
●/●
0.01/0.01
0.01
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
PM
V/f Constant Reference
Torque
control
control
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1