Toshiba Tosvert VF-AS1 Instruction Manual page 272

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

[11] Preset speed operation frequency (8~15)
Communi
Title
cation
Function
No.
Preset speed operation

0287
frequency 8
Preset speed operation

0288
frequency 9
Preset speed operation

0289
frequency 10
Preset speed operation

0290
frequency 11
Preset speed operation

0291
frequency 12
Preset speed operation

0292
frequency 13
Preset speed operation
0293

frequency 14
Preset speed operation
0294
frequency 15

(Forced operation frequency)
[12] Tripless intensification setup [1/2]
Communi
Title
cation
Function
No.
0300
PWM carrier frequency

0301
Auto-restart control selection

Regenerative power

0302
ride-through control
 0303
Retry selection

0304
Dynamic braking selection
 0305
Overvoltage limit operation
This parameter moves to a fundamental parameter.
*2: Default values vary depending on the capacity.  See the table of K-48.
Adjustment range
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
Adjustment range
1.0~16.0kHz (2.5~8.0kHz) *1
0:Disabled, 1:At auto-restart
2:When turning ST operation standby signal on or
off, 3:1+2, 4:Starting
0:Disabled, 1:Power ride-through
2:Deceleration stop during power failure
3:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration signal)
4:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration signal+power failure)
0:Deselect, 1-10 times
0:Disabled
1:Enabled (braking resistance overload detect)
2:Enabled (braking resistance overload not detect)
0:Enabled
1:Disabled
2:Enabled (quick deceleration)
3:Enabled (dynamic quick deceleration)
*1: For 200V-55/75kW models and 400V-90kW to 400V-500kW models, the carrier frequency is between 2.5 and 8.0kHz inclusive.
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
Write during
setting unit
Default
running
Speed
(Panel/Communi
setting
control
cation)
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
0.1/0.1
*2
Enabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
1/1
2
Disabled
●/●
PM
Torque
V/f
Reference
control
control
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
PM
V/f
Reference
Torque
control
control
●/●
5. 17
●/●
5. 18.1
-/-
5. 18. 2
●/●
6. 14. 1
●/●
5. 19
●/●
6. 14. 2

Advertisement

Table of Contents
loading

Table of Contents