[21] Adjustment parameters [2/2]
Communi
Title
cation
Function
No.
0469
Overvoltage limit constant
0470
VI/II input bias
0471
VI/II input gain
0472
RR/S4 input bias
0473
RR/S4 input gain
0474
RX input bias
0475
RX input gain
0476
Optional AI1 input bias
0477
Optional AI1 input gain
0478
Optional AI2 input bias
0479
Optional AI2 input gain
Max output voltage modulation
0495
rate
PM motor constant 1 (d axis
0498
inductance)
PM motor constant 2 (q axis
0499
inductance)
*1: Settings vary from unit to unit. Even if is set to , no change is made to these values.
[22] Acceleration/deceleration 2 [1/2]
Communi
Title
cation
Function
No.
0500
Acceleration time 2
0501
Deceleration time 2
Acceleration/deceleration 1
0502
pattern
Acceleration/deceleration 2
0503
pattern
Panel acceleration/deceleration
0504
selection
Acceleration/deceleration
0505
switching frequency 1
Acceleration S-pattern lower
0506
limit adjustment
Acceleration S-pattern upper
0507
limit adjustment
Deceleration S-pattern lower
0508
limit adjustment
*1: Default values vary depending on the capacity. See the table of K-48.
*2: Changing the parameter enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
Adjustment range
0: Automatic, 1~1000ms
0~255
0~255
0~255
0~255
0~255
0~255
0~255
0~255
0~255
0~255
0:Standard
1:Straight 100%
2:102.5%
3:105%
0~100%
0~100%
Adjustment range
0.1~6000 sec.
0.1~6000 sec.
0:Straight, 1:S-pattern 1, 2:S-pattern 2
0:Straight, 1:S-pattern 1, 2:S-pattern 2
1:Acceleration/deceleration 1
2:Acceleration/deceleration 2
3:Acceleration/deceleration 3
4:Acceleration/deceleration 4
0.0~ Hz
0~50%
0~50%
0~50%
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
-/-
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.1
10.0
Disabled
-
0.1/0.1
10.0
Disabled
-
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
0.1/0.1 *2
*1
Enabled
●/●
0.1/0.1 *2
*1
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
1
Enabled
●/●
0. 1/0.01
0.0
Enabled
●/●
1/1
10
Enabled
●/●
1/1
10
Enabled
●/●
1/1
10
Enabled
●/●
PM
Torque
V/f Constant Reference
control
control
-/-
-
●
6.14.2
●/●
●
●
6. 28
●/●
●
●
6. 28
●/●
●
●
6. 28
●/●
●
●
6. 28
●/●
●
●
6. 28
●/●
●
●
6. 28
●/●
●
●
6. 28
●/●
●
●
6. 28
●/●
●
●
6. 28
●/●
●
●
6. 28
●/●
●
●
6.27.3
-
●
-
6. 29
-
●
-
6. 29
PM
V/f Constant Reference
Torque
control
control
-
●
●
6. 30. 1
-
●
●
6. 30. 1
-
●
●
6. 30. 1
-
●
●
6. 30. 1
-
●
●
6. 30. 1
-
●
●
6. 30. 1
-
●
●
6. 30. 1
-
●
●
6. 30. 1
-
●
●
6. 30. 1