[30] My function [5/5]
Communi
Title
cation
Function
No.

0962
Analog input function target 21
Analog function assigned object

0964
21

0965
Monitor output function target 11
Monitor output function
0966

command 11
Monitor output function target
0967

21
Monitor output function
0968

command 21
Monitor output function target
0969

31
Monitor output function
0970

command 31
Monitor output function target
0971

41
Monitor output function
0972

command 41
0973
Virtual input terminal selection 1 0~135 *2

0974
Virtual input terminal selection 2 0~135 *2

0975
Virtual input terminal selection 3 0~135 *2

0976
Virtual input terminal selection 4 0~135 *2

0977
My function selection

*1:  For details, refer to Instruction Manual (E6581335) specified in Section 6.42. *2:  For the adjustment range, see the table on page K-43.
[31] Travenirse function
Communi
Title
cation
Function
No.
0980
Traverse selection

0981
Traverse acceleration time

0982
Traverse deceleration time


0983
Traverse step

0984
Traverse jump step
*1:  For details, refer to Instruction Manual (E6581337) specified in Section 6.42.
Adjustment range
0:Disabled
1:VI/II
2:RR/S4
3:RX
4:Optional AI1+, Optional AI1-
5:Optional AI2
6:Internal memory2
0~10
2000~2099:FD00~FD99
3000~3099:FE00~FE99
0:Normal monitor, 1:Max. value, 2:Min. value
2000~2099:FD00~FD99
3000~3099:FE00~FE99
0:Normal monitor, 1:Max. value, 2:Min. value
2000~2099:FD00~FD99
3000~3099:FE00~FE99
0:Normal monitor, 1:Max. value, 2:Min. value
2000~2099:FD00~FD99
3000~3099:FE00~FE99
0:Normal monitor, 1:Max. value, 2:Min. value
0:Disabled
1:My function + permission signal
2:My function always ON
Adjustment range
0:Disabled
1:Enabled
0.1~120.0 sec.
0.1~120.0 sec.
0.0~25.0%
0.0~50.0%
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
1/1
2000
Enabled
●/●
1/1
0
Enabled
●/●
1/1
2000
Enabled
●/●
1/1
0
Enabled
●/●
1/1
2000
Enabled
●/●
1/1
0
Enabled
●/●
1/1
2000
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
1/1
0
Disabled
●/●
0.1/0.1
25.0
Enabled
●/●
0.1/0.1
25.0
Enabled
●/●
0.1/0.1
10.0
Enabled
●/●
0.1/0.1
10.0
Enabled
●/●
PM
V/f Constant Reference
Torque
control
control
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
●/●
*1
PM
V/f Constant Reference
Torque
control
control
-
*1
-
*1
-
*1
-
*1
-
*1

Advertisement