Parameter setting
Positive
logic
7
Note 1: "ON" in positive logic
"OFF" in positive logic : Open collector output transistor or relay is turned off.
"ON" in negative logic : Open collector output transistor or relay is turned off.
"OFF" in negative logic : Open collector output transistor or relay is turned on.
Note 2: Alarm output check conditions are as follows.
(1) Undervoltage detected :To be checked during operation.
(2) Low current detected
(3) Overtorque detected
Sink logic/source logic
Sink logic and source logic (logic of input/output terminal) can be switched to each other.
For details, refer to Section 2.3.2.
Function
Negative
logic
Specified data output
1
Specified data output
2
Specified data output
3
Specified data output
4
Specified data output
5
Specified data output
6
Specified data output
7
Light load output
Heavy load output
Positive torque limit
Negative torque limit
Output for external rush
suppression relay
Completion of stop
positioning
L-STOP
Power failure
synchronized operation
Traverse in progress
Traverse deceleration in
progress
Part replacement alarm
Over-torque pre-alarm
Frequency command 1/
2 selection
Failure FL (Except
emergency stop)
Light load signal 1
(VFA7 compatibility)
My function output 1
My function output 2
My function output 3
My function output 4
My function output 5
My function output 6
My function output 7
My function output 8
My function output 9
My function output 10
My function output 11
My function output 12
My function output 13
My function output 14
My function output 15
My function output 16
Always OFF (for terminal
signal tests)
: Open collector output transistor or relay is turned on.
: To be checked during operation command.
: To be checked always.
Operation output specifications (in case of positive logic)
Output of the designated data in 7-bit.
ON:Load is equal to ~ set values or less.
ON:Load is larger than ~ set value.
ON:Positive torque is over the positive torque limit level.
ON:Negative torque is over the negative torque limit level.
ON:External rush suppression relay is actuated.
ON:Stop positioning has been completed.
ON:Operation at the lower limit frequency is performed
continuously.
ON:Power failure synchronized operation is performed.
ON:Traverse operation is performed.
ON:Traverse deceleration operation is performed.
Alarm:The time of replacement of parts is approaching.
ON: 70% of the or setting level is detected.
ON:Frequency command selection 2 is selected.
ON:A trip other than emergency stop has occurred.
ON:Load is equal to ~ set values or less.
ON:My function output 1 is ON.
ON:My function output 2 is ON.
ON:My function output 3 is ON.
ON:My function output 4 is ON.
ON:My function output 5 is ON.
ON:My function output 6 is ON.
ON:My function output 7 is ON.
ON:My function output 8 is ON.
ON:My function output 9 is ON.
ON:My function output 10 is ON.
ON:My function output 11 is ON.
ON:My function output 12 is ON.
ON:My function output 13 is ON.
ON:My function output 14 is ON.
ON:My function output 15 is ON.
ON:My function output 16 is ON.
Output signal always OFF
G-8