EPSON AcuLaser C1900/AcuLaser C900

2.3 Image Stabilization Control

The image stabilization control as described below is performed to stabilize the output
images.
Table 2-4. Image Stabilization Control
Purpose
To stabilize image density
AIDC control
To stabilize pixel depth
To stabilize transfer
Transfer output control
AIDC detection
Measures the amount of toner adhering to the transfer belt and stabilizes color
reproducibility.
Toner Adhesion
Much
Little
1.
An LED radiates infrared rays onto the toner pattern on the transfer belt.
2.
The light receiver detects the infrared rays reflected by the toner pattern on the transfer
belt.
3.
A voltage corresponding to the intensity of the reflected light is output to the Main
Board Assy (PWB-A).
AIDC sensor
Operating Principles
Control
Sensor
AIDC sensor (AIDC detection)
Temperature/humidity sensor
Reflected Light
Output
Small quantity
Low
Large quantity
High
Outline of AIDC control
AIDC control as described below is performed to ensure image stabilization.
Control
Ds correction control
LED light adjustment
control
Belt surface level correction
control
Solid color toner adhesion
control
Laser light adjustment
control
Gamma correction control
Ds correction control
Sets an optimum development bias to prevent image fogging or uneven density.
LED light adjustment control
Adjusts the quantity of light emitted by the LED to ensure a constant output value
from the sensor relative to the surface of the intermediate transfer belt to which no
toner is adhering, in order to control the fluctuation in characteristics the AIDC
sensor which can occur due to the lapse of time or dirt.
Belt surface level correction control
Measures the variation of the reflection factor of the intermediate transfer belt due
to the lapse of time and uses the measurement result for correction in the laser light
adjustment control and gamma correction control.
Solid color toner adhesion control
Adjusts the ratio of the pulse width of development bias to ensure a constant
amount of toner adhesion (amount of development) formed on the OPC drum
relative to 100% solid image.
Image Stabilization Control
Table 2-5. AIDC Control Items
Description
Sets development bias.
Adjusts the quantity of light to be emitted by the LED.
Used for laser light adjustment and gamma correction control.
Keeps the amount of toner adhesion to the OPC drum at a
constant level.
Ensures a constant level of black line reproduction and white
line reproduction.
Adjusts the quantity of laser light for a certain amount of toner
consumed.
Corrects the pixel depth by the controller.