EPSON AcuLaser C1900/AcuLaser C900
ERROR CODE: E024
"FUSER ROLLER TEMPERATURE INCREASE PROBLEM"
ERROR CODE: E025 "FUSER ROLLER LOW TEMPERATURE PROBLEM"
Detection Timing
When 80°C is not reached in 100 seconds after start of warming up.
When the fusing roller temperature has dropped and remained below 70°C for 10
seconds during standby.
Solution
Electric parts which can cause the trouble:
Fusing Roller Heater Lamp (H1)
Pressure Roller Heater Lamp (H2)
Thermostat (TS1)
Engine Board (PWB-A)
Power Supply Unit (PU)
Yes/
Step
Check Item
No
1
Check the continuity of H1
NO Replace the H1, H2.
and H2.
2
Check the continuity of TS1.
NO Replace the TS1.
3
Check to see if the resistance
YES Clean TH1 or replace
of TH1 is infinite.
(Between CN18-1 and 2 on
NO Replace the PU.
thermistor side)
Troubleshooting
Table 3-14.
WARNING
DIAGRAM
Remedy
Control Signal
HEATER
the Fuser Unit.
Replace the PWB-A.
Status Display (AcuLaser C1900)
ERROR CODE: E026
"FUSER ROLLER HIGH TEMPERATURE PROBLEM"
ERROR CODE: E027 "FUSER ROLLER THERMISTOR PROBLEM"
Detection Timing
When the Fuser Roller temperature is 220°C or higher for 0.1 second.
When between 40 seconds and 50 seconds after start of warming up of the Fuser
Roller, the Fuser Roller temperature does not rise for one second by 5°C from that at
start of fuser warming up.
Solution
Electric parts which can cause the trouble:
Thermistor (TH1)
Engine Board (PWB-A)
Step
Check Item
1
Check to see if TH1 is
shorted.
-
(Between CN18-1 and 2 on
thermistor side)
-
Table 3-15.
WARNING
Yes/
DIAGRAM
Remedy
No
Control Signal
YES Clean TH1.
HEATER
Replace the Fuser Unit.
NO Replace the PU.
Replace the PWB-A.
Revision B
129