Paper Empty Sensor - Epson AcuLaser C1900 Service Manual

A4 color page printer
Hide thumbs Also See for AcuLaser C1900:
Table of Contents

Advertisement

EPSON AcuLaser C1900/AcuLaser C900

4.5.12 Paper Empty Sensor

1.
Remove the Upper Front Cover. (p.177)
2.
Remove the Top Cover. (p.177)
3.
Remove the Front Door. (p.178)
4.
Remove the Left Cover. (p.179)
5.
Remove the Multi Purpose Tray. (p.192)
6.
Remove the Try Bottom Cover by using a mini-screw driver. (2 screws)
(See "Figure 4-37 (p.193)")
7.
Remove the Sensor Fixing Plate and then disconnect the connector. (1 connector)
8.
Remove the Paper Empty Sensor.
(See "Figure 4-38 (p.193)")
Figure 4-37. Tray Bottom Cover Removal
Disassembly and Assembly
Printer Main Parts Disassembly and Assembly
Figure 4-38. Paper Empty Sensor Removal
Install the actuator of the sensor, with attention paid to the fitting
shape of the shaft, in the orientation as shown in Figure 4-38 above.