Storage And Transport Environments Of The Packaged Printer Main Unit And Optional Products; Electrical Feature - Epson AcuLaser C1900 Service Manual

A4 color page printer
Hide thumbs Also See for AcuLaser C1900:
Table of Contents

Advertisement

EPSON AcuLaser C1900/AcuLaser C900
1.2.6 Storage and Transport Environments of the
Packaged Printer Main Unit and Optional Products
NOTE: Including Bundled Consumables
Temperature and Humidity Conditions
Temperature
0 to 35 °C
Normal Conditions
Severe Conditions
High temperature:
35 ~ 40 °C
*1
Low temperature:
-20 ~ 0 °C
Note *1: 35 ~ 55 °C when the DEVELOPER cartridges and photoconductor unit are
uninstalled.
*2: Condensation must be avoided.
Barometric Pressure for Storage (Altitude):741 ~ 1013 hPa
NOTE: 1 613 ~ 1013 hPa when the DEVELOPER cartridges and
photoconductor unit are uninstalled.
Dropping
: No damage must occur for packaged products in dropping from
52 cm height, and in 1 corner, 3 edges, 6 sides of direction.
Compliant with the EPSON transport assessment standard (T-
AE05-001-001).
Vibration
: Must conform to the JIS Z0200-1999 level 1
Compression
: Refer to Packing Specifications.
Size
: Refer to Packing Specifications.
Weight
: Refer to Packing Specifications.
Loading
: Refer to Packing Specifications.
Pallet Size
: Refer to Packing Specifications.
Product Description
Table 1-19.
Humidity
Warranty period
*2
30 to 85% RH
18 month after production
High humidity:
1/30 of 18 months
85 ~ 95% RH
*2
Low humidity:
*2
10 ~ 30% RH

1.2.7 Electrical Feature

In the following items, all options are excluded.
Fast Transient / Burst (AC Line Noise)
The following conditions shall be met in the "IEC61000-4-4" compliant evaluation.
1kV
: No error excepting minor dot errors.
1.8kV
: No Component damaged.
Instantaneous Outages
DIP 100% of instantaneous outages (at rated voltage - 10%) for 1-cycle
No deterioration in the printing quality.
The following condition shall be met in the "IEC61000-4-11" compliant
evaluation.
• 95% lowered 0.5 cycle
• 30% lowered 25 cycle
• 95% lowered 250 cycle
Resistance to Static Electricity
The following condition shall be met in the "IEC61000-4-2" compliant evaluation.
Contact discharge 8 kV
Discharge into the air 15 kV
Inrush Current
1/2-cycle
<Reference: Actually measured value including heater inrush>
• 100V: 1/2 cycle 88.0 A (0-peak)
• 120V: 1/2 cycle 66.0 A (0-peak)
• 220V: 1/2 cycle 35.6 A (0-peak)
• 240V: 1/2 cycle 38.0 A (0-peak)
(By cold start at 23°C)
Insulation Resistance
10 MΩ or more
Basic Specifications
: No error excepting minor dot errors.
: No component damaged.
: No component damaged.
: No error in any devices.
: No error in any devices.
°
: 50 A or less (0-peak) (At 23
C or higher)
Revision B