EPSON AcuLaser C1900/AcuLaser C900
ERROR CODE: E021
"TRANSFER BELT CLEANER CONTACT/RELEASE PROBLEM"
Detection Timing
When pressing or separation of the Transfer Belt Cleaner is impossible.
Solution
Electric parts which can cause the trouble:
•
Cleaner Pressure Flapper Solenoid (SL4)
•
Belt Cleaner Position Detect Sensor (PC9)
Engine Board (PWB-A)
•
Step
Action
1
Check the operation of PC9.
2
Replace the pressing/separation
mechanism parts of the Belt
Cleaner.
3
Check the operation of SL4.
4
Replace the PWB-A.
ERROR CODE: E022 "TRANSFER BELT ROTATION PROBLEM"
Detection Timing
When the transfer belt of the Transfer Belt Unit does not operate.
Solution
Step
Action
1
Replace the transfer belt unit.
Troubleshooting
Table 3-11.
WARNING DIAGRAM
Refer to
Control Signal
p.162
PC9_ON
-
-
p.163
SL4_REM
-
-
Table 3-12.
WARNING DIAGRAM
Refer to
Control Signal
-
-
Status Display (AcuLaser C1900)
ERROR CODE: E023 "IMAGING RACK ROTATION PROBLEM"
Detection Timing
When the Toner Cartridge Rack does not turn.
Solution
Electric parts which can cause the trouble:
•
Rack motor (M2)
Rack Clutch (CL1)
•
Rack Black Position Detection Sensor (PC4)
•
•
Engine Board (PWB-A)
Step
Action
1
Check the operation of PC4.
2
Check the operation of M2.
3
Check the operation of CL1.
4
Replace the PWB-A.
Revision B
Table 3-13.
WARNING DIAGRAM
Refer to
Control Signal
p.162
PC4_ON
p.163
CL1_REM
p.163
-
-
-