Programmer's Guide, cont'd

Command/Response Table for SIS Commands

Symbol definitions
Symbols are used throughout the table to represent variables in the command/
response fields. Command and response examples are shown throughout the table.
N
Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit numbers. All input and output numbers are
reported as 2-digit numbers in the response.
]
= CR/LF (carriage return/line feed) (hex 0D 0A)
}
= Carriage return (no line feed, hex 0D))
= Space character
E
= Escape key (hex 1B)
X!
= Input number
X@
= Input number (for tie)
X#
= Output number
X$
= Mute, Lock mode, power supply
X%
= Audio gain
X^
= Numeric dB value
X&
= Audio attenuation
X*
= Volume adjustment range
X(
= Global or room preset #
N
A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from
memory, it becomes the current configuration.
X1)
= Room # (for room presets)
N
A Room is a subset of operator-selected outputs that relate to each other. The CrossPoint or MAV Plus switchers support up to 10
rooms, each of which can consist of from 1 to 16 outputs.
X1!
= Name
N
The following characters are invalid in the name: {space} ~ , @ = ' [ ] { } < > ' " ; : | \ and ?.
X1@
= Video/audio mute:
X1#
= Sync frequency
X1$
= Connection status
X1%
= RGB delay interval
X1^
= Group # (for I/O grouping)
X1&
= Inputs
X1*
= Outputs
X1(
= Part number
X2)
= Firmware version number to second decimal place (x.xx)
X2!
= Verbose firmware version-description-upload date/time.
See the Query controller firmware version (verbose) command on page 4-19.
X2@
= Voltage
X2#
= Temperature
X2$
= Fan speed
4-8
CrossPoint / MAV Matrix Switchers • Programmer's Guide
01 – (maximum number of inputs for your model)
00 – (maximum number of inputs for your model) (00 = untied)
01 – (maximum number of outputs for your model)
0 = off/mode 0/not OK
1 = on/mode 1/OK
2 = mode 2
0 – 24 (1 dB/step)
–18 to +24 (45 steps of gain or attenuation) (default = 0 dB)
1 – 18 (1 dB/step)
0 – 64 (1 dB/step except for 0-to-1, which is 22 dB)
(default = 64 [0 dB])
(See the table on page 4-11.)
00 - 32, 10 maximum for a room preset (00 = current configuration)
10 max. (Each can have up to 10 presets (
12 characters maximum for input, output, and global preset names
11 characters maximum for room names
Upper- and lower-case alphanumeric characters and
_ / and spaces are valid.
0 = no mutes
1 = video mute
2 = audio mute
3 = video and audio mute
xxx.xx (frequency in hZ [V] or kHz [H])
0 = no input connected
1 = input connected
Delay in 1/2 second increments (10 maximum)
1 through 4 groups (0 = no group)
Total number of inputs for this switcher
Total number of outputs for this switcher
60-nnn-nn (See appendix B, "Reference Information".)
Positive or negative voltage and magnitude
Degrees Fahrenheit
RPM
X(
s) assigned.)

Hide quick links: