Perform a soft reset of the switcher as follows:
1.
Use an Extron Tweeker or other small screwdriver to press and hold the rear
panel Reset button until the front panel Video and Audio buttons blink once
(events reset), twice (system reset), or three times (absolute reset) (figure 3-82).
Press and hold
the Reset button.
Events Reset
Press and hold
the Reset button.
IP Settings
Reset
Press and hold
the Reset button.
Absolute Reset
Figure 3-82 — Whole switcher and absolute resets
2.
Release the Reset button and then immediately press and release the Reset
button again. Nothing happens if the second momentary press does not occur
within 1 second.
CrossPoint / MAV Matrix Switchers • Operation
Reset LED flashes once.
3 seconds
Front panel I/O buttons flash once.
I / O
RGBHV AUDIO
Reset LED flashes twice.
6 seconds
Front panel I/O buttons flash twice.
I / O
RGBHV AUDIO
Reset LED flashes
three times.
9 seconds
Front panel I/O buttons flash three times.
I / O
RGBHV AUDIO
Release, then immediately
press and release again.
Release, then immediately
press and release again.
Release, then immediately
press and release again.