8. MEMORY CARTRIDGE

The Memory Cartridge can be effectively used for saving further Patch Memory or Tone data.
The Memory Cartridge is essential to store more Patch Memory or Tone data, while the main Patch Memory and
Tone data can be retained in the internal memory. The entire data of the JX-10's internal memory can be
transferred to the Cartridge memory, and also the data in the Cartridge memory can be loaded back to the internal
memory.
As an alternative, thanks to the improved and updated MIDI implementation, the bulk/load procedure from/to the
instrument can be achieved with dedicated softwares such as Emagic SoundDiver and SoundQuest MidiQuest.
a. Copying the Entire Data (All Patch Memories and 50 Tones)
All the 64 Patch Memories and the 50 Tones can be copied to the Memory Cartridge M-64C, and loaded it back to
the JX-10's internal memory at any time.
1) Saving
1. Set the Protect Switch on the Memory Cartridge to the OFF position.
2. While holding the WRITE Button on the JX-10 down, push the INT ▼ CART of the Copy Buttons
The Display will respond with:
3. Push the Enter Key.
When the Display shows as above, saving is complete. In a few seconds, the Display will return to the Patch
Memory indication.
4. Return the Protect Switch on the Memory Cartridge to the ON position.
2) Loading
1. Set the Protect Switch on the Memory Cartridge to the OFF position.
2. While holding the WRITE Button on the JX-10 down, push the CART ▲ INT of the Copy Buttons
The Display will respond with:
3. Push the Enter Key.
When the Display shows as above, loading is completed. In a few seconds, the Display will return to the
Patch Memory indication.
4. Return the protect Switch on the JX-10 to the ON position.