b. Copying a Patch Memory
The JX-10 allows to copy only one Patch Memory onto the Memory Cartridge or load one Patch Memory from the
Cartridge memory to the internal memory.
1) Saving a single Patch Memory onto the Cartridge
1. Set the Protect Switch on the Memory Cartridge to the OFF position.
2. Set the Voice Memory Switch to the INT position.
3. Call the Patch Memory to be saved onto the Cartridge.
4. Push the WRITE Button
The Display will respond with:
5. Push the PATCH of the Edit Buttons
6. Set the Voice Memory Switch to the CART position.
7. Using the Patch Memory Buttons, assign the Bank and the Number of the Patch Memory that is to be the new
location for the Patch Memory you have selected in the step 3.
8. Push the Enter Key.
9. Return the Protect Switch on the Memory Cartridge to the ON position.
2) Loading a single Patch Memory to the JX-10's internal memory
1. Set the Protect Switch on the JX-10 to the OFF position.
2. Set the Voice Memory Switch to the CART position.
3. Call the Patch Memory to be copied to the JX-10.
4. Push the WRITE Button
The Display will respond with:
5. Push the PATCH of the Edit Buttons.
6. Set the Voice Memory Switch to the INT position.
7. Using the Patch Memory Buttons, assign the Bank and the Number of the new location on the JX-10 where the
Patch Memory you have called in the step 3 is to be copied.
8. Push the Enter Key.
9. Return the Protect Switch on the JX-10 to the ON position.
NOTE
When a Patch Memory is copied from the internal memory to the Cartridge and vice versa, the Tones used for the
Patch Memory are also copied. Therefore corresponding Tone numbers will be rewritten.
Roland JX-10 Manual – Firmware ver 3.00 ADDENDUM