4
Remove the LVPS. See
5
Remove the left cover. See
6
Remove the PCBA housing. See
7
Remove the main drive motor. See
8
Remove the harnesses from the clamp (A).
9
Remove the three screws (B) securing the fuser drive motor to the machine.
Note: When removing the lowermost screw, the grounding plate will become detached.
10
Disconnect the cable (C) from the fuser drive motor.