Fujitsu fi-6000NS Operator's Manual page 62

Juniper networks network scanner operator's guide
Hide thumbs Also See for fi-6000NS:
Table of Contents

Advertisement

5. Trace a line on the screen with your fingertip.
A corresponding line will appear on-screen.
If the line does not appear correctly, press the [Calib screen] button to return to Step 4.
If the screen becomes cluttered, press the [CLR screen] button to remove all the lines.
HINT
6. When you are satisfied with the touch screen response, press the [Update] button.
This saves the current calibration data, completing the calibration process, and returns
you to the "Screen Calibration" screen.
ATTENTION
36
Press the [Cursor on/off] button to toggle the mouse cursor between
its "visible" and "hidden" states.
If the calibration is not performed carefully, or the [Enter] key is
pressed before all the calibration points have been touched, the
following error message may appear:
Parameter Error. Please input, again.
Press the [Enter] key to dismiss the error dialog, and perform the
calibration from Step 4 again, being careful to touch each calibration
point accurately.