Figure 18 Menu 11.1 - Remote Node Profile; Table 12 Menu 11.1 Remote Node Profile - Nortel BCM50a Configuration Manual

Integrated router
Table of Contents

Advertisement

72 Chapter 6 Remote Node setup
Figure 18 Menu 11.1 – Remote Node Profile
Menu 11.1 - Remote Node Profile
Press Space Bar to Toggle.
Table 12

Table 12 Menu 11.1 Remote Node Profile

Field
Rem Node
Name
Active
N0115791
Selecting RFC-1483 encapsulation with VC-based multiplexing requires the
least amount of overhead (0 octets). However, if there is a potential need for
multiple protocol support in the future, it may be safer to select PPPoA
encapsulation instead of RFC-1483, so you do not need to reconfigure either
computer later.
Scenario 3.Multiple VCs
If you have an equal number (or more) of VCs than the number of protocols,
then select RFC-1483 encapsulation and VC-based multiplexing.
Rem Node Name= ChangeMe
Active= Yes
Encapsulation= ENET ENCAP
Multiplexing= LLC-based
Service Name= N/A
Incoming:
Rem Login= N/A
Rem Password= N/A
Outgoing:
My Login= N/A
My Password= N/A
Authen= N/A
Press ENTER to Confirm or ESC to Cancel:
describes fields in
Description
Type a unique, descriptive name of up to eight characters
for this node.
Press [SPACE BAR] and then [ENTER] to select Yes to
activate or No to deactivate this node. Inactive nodes are
displayed with a minus sign "–" in SMT menu 11.
Route= IP
Bridge= No
Edit IP/Bridge= No
Edit ATM Options= No
Edit Advance Options= N/A
Telco Option:
Session Options:
Figure
18.
Allocated Budget(min)= N/A
Period(hr)= N/A
Schedule Sets= N/A
Nailed-Up Connection= N/A
Edit Filter Sets= No
Idle Timeout(sec)= N/A
Example
myISP
Yes

Advertisement

Table of Contents
loading