Nortel Secure Router 4134 Quick Start Manual

Nortel networks secure router quick start guide
Hide thumbs Also See for Nortel Secure Router 4134:
Table of Contents

Advertisement

Nortel Secure Router 4134
Quick Start
Release: 10.1
Document Revision: 02.01
www.nortel.com
NN47263-100
323245-B
.

Advertisement

Table of Contents
loading

Summary of Contents for Nortel Nortel Secure Router 4134

  • Page 1 Nortel Secure Router 4134 Quick Start Release: 10.1 Document Revision: 02.01 www.nortel.com NN47263-100 323245-B...
  • Page 2 Nortel Networks. Except as expressly authorized in writing by Nortel Networks, the holder is granted no rights to use the information contained herein and this document shall not be published, copied, produced or reproduced, modified, translated, compiled, distributed, displayed or transmitted, in whole or part, in any form or media.
  • Page 3: Table Of Contents

    Module protection 18 Cables and connectors protection 19 Electrostatic discharge 19 Antistatic material 20 New in this release Features 21 Interface modules 21 Copyright © 2007, 2008 Nortel Networks Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008...
  • Page 4 Translations of safety messages Class A device caution statement 63 Qualified service personnel warning statement 64 Overcurrent warning statement 65 Cover plate warning statement 66 Copyright © 2007, 2008 Nortel Networks Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008...
  • Page 5 Power cord warning statement 67 Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008 Copyright © 2007, 2008 Nortel Networks...
  • Page 6 Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008 Copyright © 2007, 2008 Nortel Networks...
  • Page 7: Secure Router 4134 Regulatory Information And Safety Precautions

    International Regulatory Statements of Conformity This is to certify that the Nortel Secure Router 4134 equipment was evaluated to the international regulatory standards for electromagnetic compliance (EMC) and safety and were found to have met the requirements for the following international standards: •...
  • Page 8: Tia-968-A

    CE marking statement (Europe only) EN 55022 statements This is to certify that the Nortel Secure Router 4134 equipment is shielded against the generation of radio interference in accordance with the application of Council Directive 2004/108/EC. Conformity is declared by the application of EN 55022 Class A (CISPR 22).
  • Page 9: European Union And European Free Trade Association (Efta) Notice

    National Electromagnetic Compliance (EMC) Statements of Compliance 9 EN 55024 statement This is to certify that the Nortel Secure Router 4134 is shielded against the susceptibility to radio interference in accordance with the application of Council Directive 2004/108/EC. Conformity is declared by the application of EN 55024 (CISPR 24).
  • Page 10: Vcci Statement (Japan/Nippon Only)

    Observe the Regulatory Marking label on the back or bottom of each switch for specific certification information pertaining to this model. Each Nortel Secure Router 4134 model is approved for shipment to/usage in Korea and is labeled as such, with all appropriate text and the appropriate MIC reference number.
  • Page 11: National Safety Statements Of Compliance

    National Safety Statements of Compliance EN 60950 statement This is to certify that the Nortel Secure Router 4134 equipment is in compliance with the requirements of EN 60950 in accordance with the Low Voltage Directive. Additional national differences for all European Union countries have been evaluated for compliance.
  • Page 12: Denan Statement (Japan/Nippon Only)

    12 Secure Router 4134 regulatory information and safety precautions Exportador: Nortel Networks, 5400 Hellyer Ave, San Jose, CA 95138 USA. Importador: Nortel Networks de México, S.A. de C.V. Avenida Insurgentes Sur #1605 Piso 30, Oficina Col. San Jose Insurgentes Deleg-Benito Juarez México D.F. 03900 52 5 480 2100...
  • Page 13: Weee Directive Compliance Statement

    This section describes the precautionary notices you find in this document. This section also contains precautionary notices that you must read for safe operation of the Nortel Secure Router 4134. Notices Notice paragraphs alert you about issues that require your attention. The following paragraphs describe the types of notices used in this guide.
  • Page 14 14 Secure Router 4134 regulatory information and safety precautions Copyright © 2007, 2008 Nortel Networks CAUTION Caution notices provide information about how to avoid possible service disruption or damage to Nortel products. CAUTION ACHTUNG Achtungshinweise bieten Informationen dazu, wie man mögliche Dienstunterbrechungen oder Schäden an Nortel-Produkten...
  • Page 15: Cautions And Warnings For The Secure Router 4134

    The following precautionary messages apply to the Secure Router 4134. For your safety, read these precautions carefully before proceeding with installation of the product. Copyright © 2007, 2008 Nortel Networks WARNING Only qualified service personnel must perform installation. Read and follow all warning notices and instructions marked on the product or included in the documentation.
  • Page 16 10 years in the absence of power. Nortel does not consider the lithium battery in this unit a field replaceable or serviceable part and should not be accessed by the customer. Copyright © 2007, 2008 Nortel Networks CAUTION Risk of explosion if battery is replaced by an incorrect type.
  • Page 17: Foreign Exchange Station (Fxs) Interface Modules

    RING. FXS ground start does not work if polarity is reversed. ATTENTION Nortel does not support FXS port connections leaving the building. Use FXS connections for intra-building purposes only. Copyright © 2007, 2008 Nortel Networks WARNING WARNUNG Risiko einer Augenverletzung durch Laser Glasfasergeräte können Laserstrahlen oder ultraviolettes Licht...
  • Page 18: Foreign Exchange Office (Fxo) Interface Modules

    You must fill all slots with modules or slot covers to maintain safety compliance, proper cooling, and electromagnetic interference (EMI) containment in the shelf. Copyright © 2007, 2008 Nortel Networks WARNING The 2- and 4-port FXS interface modules have a ring signal generator that is a source of hazardous voltage.
  • Page 19: Cables And Connectors Protection

    ESD can cause equipment to malfunction or fail. To dissipate or neutralize electrostatic charges, use proper grounding and use conductive or dissipative materials. Copyright © 2007, 2008 Nortel Networks Personal safety and equipment protection 19 “Environmental requirements” (page Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 20: Antistatic Material

    Place modules on an appropriate antistatic material when you replace hardware. Use an ESD pad or antistatic packaging. ATTENTION Some antistatic packaging is effective only on the inside of the package. Copyright © 2007, 2008 Nortel Networks Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008...
  • Page 21: New In This Release

    New in this release The following section details what’s new in the Nortel Secure Router 4134 — Quick Start (NN47263-100) for Release 10.1. Features See the following sections for information about feature changes: • “Interface modules” (page 21) Interface modules Secure Router 4134, Release 10.1, introduces six new external interface...
  • Page 22: Nn47263-100 02.01 Standard 18 February

    22 New in this release Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008 Copyright © 2007, 2008 Nortel Networks...
  • Page 23: Introduction

    Introduction Nortel Secure Router 4134 — Quick Start (NN47263-100) provides basic instruction on how to install the hardware and perform initial configuration of the Nortel Secure Router 4134. The Quick Start is intended for experienced installers. Navigation • “Installing the Secure Router 4134 chassis and hardware components”...
  • Page 24 24 Introduction Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008 Copyright © 2007, 2008 Nortel Networks...
  • Page 25: Secure Router 4134 Installation And Initial Configuration

    This work flow shows you the sequence of tasks you perform to install the Secure Router 4134 and prepare the unit for system configuration. To link to any task, go to navigation” (page Copyright © 2007, 2008 Nortel Networks “Secure Router 4134 installation and initial configuration 27). Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 26 26 Secure Router 4134 installation and initial configuration Figure 1 Secure Router 4134 installation and initial configuration tasks Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008 Copyright © 2007, 2008 Nortel Networks...
  • Page 27: Secure Router 4134 Installation And Initial Configuration Navigation

    “Connecting a terminal for local access” (page 55) • “Establishing remote access” (page 56) • “Changing the default administrator password” (page 58) Copyright © 2007, 2008 Nortel Networks Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008...
  • Page 28 28 Secure Router 4134 installation and initial configuration Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008 Copyright © 2007, 2008 Nortel Networks...
  • Page 29: Installing The Secure Router 4134 Chassis And Hardware Components

    Installing the Secure Router 4134 chassis and hardware components For detailed instructions about how to install the Secure Router 4134 and its hardware components, see Nortel Secure Router 4134 Installation — Chassis (NN47263-300) and Nortel Secure Router 4134 Installation — Hardware Components (NN47263-301).
  • Page 30: Installing A Power Supply Module

    DC power supplies, or one AC and one DC power supply. You install the power supplies at the rear of the unit. Average time to install one power supply module: 1 minute. Copyright © 2007, 2008 Nortel Networks CAUTION Risk of equipment damage Watch the power supply status LED for alerts if you hot swap a power supply module.
  • Page 31: Prerequisites

    You can mount the Secure Router 4134 with either the front panel or the back panel facing the operator. The following table shows the six possible mounting positions. Copyright © 2007, 2008 Nortel Networks Installing the mounting brackets on the chassis 31 CAUTION...
  • Page 32 Position 1 with front panel facing operator Position 2 with front panel facing operator Position 3 with front panel facing operator Copyright © 2007, 2008 Nortel Networks Description Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008...
  • Page 33: Prerequisites

    Ensure you have the rack mounting brackets and screws that shipped with the Secure Router 4134. • Ensure you have a Phillips #2 screwdriver. Copyright © 2007, 2008 Nortel Networks Installing the mounting brackets on the chassis 33 Description Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 34: Installing The Chassis

    Nortel recommends that you install the chassis (including the power supplies and fan tray) in the equipment rack before you install the ground lug and the optional external interface modules. Copyright © 2007, 2008 Nortel Networks --End-- WARNING Do not install the Secure Router 4134 near a standing or running water source or in a high-humidity environment.
  • Page 35: Prerequisites

    Ensure you have allotted adequate space in and around the equipment rack for installation of the Secure Router 4134. • Ensure you have the screws that shipped with the chassis. Copyright © 2007, 2008 Nortel Networks WARNING Risk of injury The Secure Router 4134 weighs approximately 25 lb (11.34 kg) with one power supply and the fan tray installed.
  • Page 36: Grounding The Chassis

    ATTENTION You must install the Secure Router 4134 in a restricted-access location. You must limit access to the Secure Router 4134 to authorized service personnel only. Copyright © 2007, 2008 Nortel Networks --End-- Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008 “Environmental requirements”...
  • Page 37: Prerequisites

    ATTENTION ACHTUNG Sie müssen Schutzleitungen mit dem Erdanschluss verbinden, wenn der Wechselstrom von externen Netzteilen stammt. Copyright © 2007, 2008 Nortel Networks WARNING Disconnect the Secure Router 4134 from all power sources (AC and DC) before servicing. WARNING La prudence: Proteger contre le risque de choc electrique, debrancher les cordes d’alimentation et DC telegraphiant avant...
  • Page 38 Secure the ground lug with two 8-32 screws and washers (provided), ensuring the barrel faces down, as shown in the following figure. Copyright © 2007, 2008 Nortel Networks CAUTION ACHTUNG Stellen Sie als allgemeine Sicherheitsmaßnahme sicher, dass der Wechselstrom durch einen Trennschalter auf dem Geräteträger fließt.
  • Page 39: Installing The Interface Modules

    (ports 0/3 and 0/4) on the front panel of the Secure Router 4134. The legend shows how slots are numbered on the Secure Router 4134. The following figure shows the slot numbering legend. Copyright © 2007, 2008 Nortel Networks Installing the interface modules 39 Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 40 If you insert a Large Module, it spans slots 6 and 7. If you install a Large Module, slots 6 and 7 become slot 6. For detailed information about the Secure Router 4134 modules, see Nortel Secure Router 4134 Installation — Hardware Components (NN47263-301). Average time to install an interface module: 1 minute.
  • Page 41: Prerequisites

    Align the module with the slot and the slot module guides. Slide the module into the chassis until its connector panel touches the chassis back panel. Copyright © 2007, 2008 Nortel Networks CAUTION Risk of equipment damage Always handle interface modules by the edges, or use the levers, where applicable.
  • Page 42: Installing A Medium Module

    Router 4134. You can install a Large Module to span slots 6 and 7 only. Procedure steps Step Action Use a Phillips screwdriver to remove the slot cover plates from slots 6 and 7. Copyright © 2007, 2008 Nortel Networks --End-- --End-- Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 43: Installing A Small Module In The Voice Carrier Medium Module

    If you are working with 2- or 4-port FXS or FXO Small Modules, ensure you read the safety messages related to the FXS and FXO interface modules. See “Foreign Exchange Office (FXO) Interface Modules” (page Copyright © 2007, 2008 Nortel Networks Installing the interface modules 43 --End-- “Installing a Medium Module” (page “Foreign Exchange Station (FXS) Interface Modules”...
  • Page 44 Figure 4 Voice Carrier Medium Module slot numbering For detailed information about the Voice Carrier Medium Module, see Nortel Secure Router 4134 Installation — Hardware Components (NN47263-301). Average time to install a Small Module in the Voice Carrier Medium Module: 1 minute Copyright ©...
  • Page 45 Small Module connector touches the back panel of the Voice Carrier Medium Module. Push gently, but firmly, to seat the Small Module connector in the Voice Carrier Medium Module. Copyright © 2007, 2008 Nortel Networks Installing the interface modules 45 CAUTION Risk of equipment damage Always handle interface modules by the edges, or use the levers, where applicable.
  • Page 46: Connecting Power Cables

    • Ensure the power cord or cords are long enough to plug the male end into a standard 110/220 V AC power outlet. Copyright © 2007, 2008 Nortel Networks --End-- CAUTION Always wear an ESD-preventative wrist strap when you connect cables or perform maintenance on a Secure Router 4134.
  • Page 47: Connecting Dc Power

    Connecting DC power The following figure shows the location of the terminal block on the DC power supply module. Copyright © 2007, 2008 Nortel Networks CAUTION Ensure you use an appropriately rated AC power cord only. Do not use an extension cord.
  • Page 48 Figure 5 Secure Router 4134 DC power supply terminal block Average time to install one DC power cable: 3 minutes. Copyright © 2007, 2008 Nortel Networks CAUTION Always wear an ESD-preventative wrist strap when you connect cables or perform maintenance on a Secure Router 4134.
  • Page 49 Action Switch off the DC power source. Loosen both terminal cover screws on the DC power supply, as shown in the following figure. Copyright © 2007, 2008 Nortel Networks CAUTION ACHTUNG Stellen Sie als allgemeine Sicherheitsmaßnahme sicher, dass der Wechselstrom entweder durch eine Sicherung oder einen Wechselstromsicherung mit maximal 12 A fließt.
  • Page 50 Remove the terminal cover to expose the terminal block. Insert the –48 V lead behind the –48 V terminal, as shown in the following figure. Copyright © 2007, 2008 Nortel Networks Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 51 Secure Router 4134. Attach the other ends of the leads to a –48 V DC power source. Copyright © 2007, 2008 Nortel Networks --End-- Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 52: Powering Up The Router

    The fan tray red (fail) LED can illuminate briefly while the fans power to operational speed. If status LEDs do not illuminate green, see Nortel Secure Router 4134 — Troubleshooting (NN47263-700). Verifying a successful installation Use the information in this section to verify that you have successfully installed the Secure Router 4134 and its components.
  • Page 53 Secure Router 4134 do not illuminate green, refer to the LEDs on the modules to identify issues. The logon prompt appears on the console screen. Copyright © 2007, 2008 Nortel Networks Verifying a successful installation 53 Rear panel LEDs...
  • Page 54 54 Installing the Secure Router 4134 chassis and hardware components Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008 Copyright © 2007, 2008 Nortel Networks...
  • Page 55: Configuring The Secure Router 4134 For Remote Access

    Secure Router 4134 using the console cable that ships with the unit. Copyright © 2007, 2008 Nortel Networks Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 56: Prerequisites

    Configure the IP address for the management port. Configure the next hop (gateway IP address). Verify a successful connection. Enable remote access. You can enable SSH or Telnet for remote connections. Copyright © 2007, 2008 Nortel Networks --End-- Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 57: Using Ssh For Remote Access

    IP address is active. To enable the Telnet server services, enter: telnet_server Using SSH for remote access You can enable an SSH connection for remote access. Copyright © 2007, 2008 Nortel Networks --End-- Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 58: Changing The Default Administrator Password

    Commissioning (NN47263-302). To configure features on your Secure Router 4134, see Nortel Secure Router 4134 — Documentation Roadmap (NN47263-103) for a list of Nortel Secure Router 4134 documents and information about the Release 10.1 features. Changing the default administrator password Nortel recommends that you change the default administrator password for security reasons.
  • Page 59 The Secure Router 4134 prompts you to verify the new password. Re-enter your new password. A message appears that confirms that the password is changed. Copyright © 2007, 2008 Nortel Networks Changing the default administrator password 59 --End-- Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard...
  • Page 60 60 Configuring the Secure Router 4134 for remote access Nortel Secure Router 4134 Quick Start NN47263-100 02.01 Standard 18 February 2008 Copyright © 2007, 2008 Nortel Networks...
  • Page 61: Environmental Requirements

    ATTENTION Install the Secure Router 4134 in a restricted-access location. Limit access to the Nortel Secure Router 4134 to authorized service personnel only. Ensure you allow 2 to 3 feet (0.61 to 0.91 m) of additional clearance around the Secure Router 4134 for access to the cable connectors on the front and rear panels.
  • Page 62 Environmental requirements for the Secure Router 4134 (cont’d.) Parameter Storage humidity Vibration Acoustic noise Copyright © 2007, 2008 Nortel Networks Range 0 to 95% R.H. (noncondensing) Packaging and shipping – ISTA 2A Office Vibration – GR-63-CORE Issue 3, Section 4.4.2 and 5.4.2 GR-63-CORE Issue 3, section 4.6 and 5.6...
  • Page 63: Translations Of Safety Messages

    Appendix Translations of safety messages Class A device caution statement Copyright © 2007, 2008 Nortel Networks CAUTION This device is a Class A product. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense.
  • Page 64: Qualified Service Personnel Warning Statement

    64 Translations of safety messages Qualified service personnel warning statement Copyright © 2007, 2008 Nortel Networks CAUTION CUIDADO Este dispositivo é um produto Classe A. Operar este equipamento em uma área residencial provavelmente causará interferência prejudicial; neste caso, espera-se que os usuários tomem as medidas necessárias para corrigir a interferência por...
  • Page 65: Overcurrent Warning Statement

    Overcurrent warning statement Copyright © 2007, 2008 Nortel Networks Overcurrent warning statement 65 WARNING AVISO Apenas profissionais de atendimento técnico qualificados devem realizar a instalação. Leia e siga todos os avisos e instruções destacados no produto ou que façam parte da documentação.
  • Page 66: Cover Plate Warning Statement

    66 Translations of safety messages Cover plate warning statement Copyright © 2007, 2008 Nortel Networks WARNING WARNUNG Die Nutzung dieses Produkts setzt einen Überstromschutz am Gebäude voraus. Stellen Sie sicher, dass eine Sicherung oder ein Trennschalter mit höchstens 120 V Wechselstrom, 15 A USA (240 V Wechselstrom, 10 A international) bei den Außenleitern verwendet wird.
  • Page 67: Nn47263-100 02.01 Standard 18 February

    Power cord warning statement Copyright © 2007, 2008 Nortel Networks Power cord warning statement 67 CAUTION ACHTUNG Wenn Sie in kein Modul in diesem Steckplatz installieren, stellen Sie sicher, dass sich die Abdeckplatte aus Metall weiterhin über dem Steckplatz befindet. Wenn die Metallplatte entfernt wird, behindert dies den Luftstrom und eine angemessene Kühlung...
  • Page 68 68 Translations of safety messages Copyright © 2007, 2008 Nortel Networks DANGER GEFAHR Verwenden Sie nur Netzkabel mit Erdungspfad. Ohne einen angemessenen Untergrund besteht für die Person, die den Schalter berührt, die Gefahr eines Stromschlags. Das Fehlen eines Erdungspfads beim Schalter führt möglicherweise zu überhöhten Emissionen.
  • Page 70: Nortel Secure Router

    This document is protected by copyright laws and international treaties. All information, copyrights and any other intellectual property rights contained in this document are the property of Nortel Networks. Except as expressly authorized in writing by Nortel Networks, the holder is granted no rights to use the information contained herein and this document shall not be published, copied, produced or reproduced, modified, translated, compiled, distributed, displayed or transmitted, in whole or part, in any form or media.