Port Management
Configuring PoE
STEP 4
Cisco Small Business SG200 Series 8-port Smart Switches Administration Guide
Power Allocation—If you configured a user-defined option for Power Limit
Type, enter the power in milliwatts to be allocated to the port, between 3000
to 16200 milliwatts.
Detection Type—Select one of the following methods to detect PoE-
powered devices connected to the ports.
-
Legacy Only—Only capacitive signature devices are detected.
-
802.3af 4point Only—Only resistive signature devices are detected
with the first algorithm.
-
802.3af 4point and Legacy—Both capacitive and resistive signature
devices are detected by using the second algorithm.
-
802.3af 2point Only—Only resistive signature devices are detected
with the first algorithm.
-
802.3af 2point and Legacy—Both capacitive and resistive signature
devices are detected using the first algorithm.
Reset Mode—Select Enable to enable the switch initialize the ports PoE
state machines.
The following statistics also appear:
Power Consumption—Actual power consumption on the port.
Overload Counter—Total number of power overload occurrences.
Short Counter—Total number of power short condition (electrical shorts) on
a port.
Denied Counter—Number of times the powered device was denied power.
Absent Counter—Number of times the power supply was stopped to the
powered device because the powered device was no longer detected.
Invalid Signature Counter—Number of times an invalid signature was
received. Signatures are the means by which the powered device identifies
itself to the PSE. A signature is generated during powered device detection,
classification, or maintenance.