Honeywell ST 3000 User Manual page 52

Smart transmitter
Hide thumbs Also See for ST 3000:
Table of Contents

Advertisement

4— Installation - Wiring ST 3000 Transmitter
The third output meter option is a meter display that can be mounted remotely in a separate housing.
SM 3000 Smart meter
Meter Output indication –
17-segment bargraph and digital readout to
show PV out in % of span.
ATTENTION
Be aware that the SM 3000 remote meter only shows PV output in % of span and does not
display transmitter output in custom or flow units like the new smart meter. Therefore, if you
use an SM 3000 remote meter in conjunction with a new smart meter that is configured to
display readings in custom or flow units, the indications of the two meters will be displayed in
different units.
38
Meter type
0
%
100
ST 3000 HART Transmitter Release 300 User Manual
Wiring Connections to Transmitter
SM 3000 smart meter connections — The smart
meter (3-wires) can be connected remotely to a
Release 300 transmitter. Section 13 in this
manual illustrates alternate wiring methods for
connecting this smart meter to Release 300
transmitters.