Needle Change On 1-Needle Machines - DURKOPP ADLER 867 Operating Manual

Hide thumbs Also See for 867:
Table of Contents

Advertisement

Operating instructions
Operating manual 867 Version 01.0 - 12/2012

5.2.1 Needle change on 1-needle machines

Figure 3: Inserting and changing needles on 1-needle machines
1
2
3
4
(1) - Needle bar
(2) - Fastening screw
1. Turn the handwheel until the needle bar (1) reaches the upper
end position.
2. Loosen the fastening screw (2).
3. Pull the needle out towards the bottom.
4. Insert the new needle.
5. Important: Align the needle so that the groove (3) faces the
hook (4).
6. Tighten the fastening screw (2).
(3) - Groove
(4) - Hook