7.12.8 Fitting the M-Control circuit board
DANGER
Danger to life due to electric shock.
Disconnect the power plug before fitting the circuit
board.
Make sure the power plug cannot be unintention-
ally reinserted.
Figure 69: Fitting the circuit board
1
(1) - Frame
1. Fitting the circuit board:
• Machines with a binder:
between the frame (1) and cable duct (2)
• Machines with switchable needle bars:
At the right next to the setpoint device angle bracket (3)
(2) - Cable duct
(3) - Setpoint device angle bracket