Fitting The M-Control Circuit Board - DURKOPP ADLER 867 Operating Manual

Hide thumbs Also See for 867:
Table of Contents

Advertisement

100

7.12.8 Fitting the M-Control circuit board

DANGER
Danger to life due to electric shock.
Disconnect the power plug before fitting the circuit
board.
Make sure the power plug cannot be unintention-
ally reinserted.
Figure 69: Fitting the circuit board
1
(1) - Frame
1. Fitting the circuit board:
• Machines with a binder:
between the frame (1) and cable duct (2)
• Machines with switchable needle bars:
At the right next to the setpoint device angle bracket (3)
(2) - Cable duct
(3) - Setpoint device angle bracket
Operating manual 867 Version 01.0 - 12/2012
Set-up instructions
3
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents