6.7
Changing the needle with single-needle machines with the hook on the right
22
1
2
3
4
5
Caution! Risk of injury!
Replace the needle with the main switch switched off and the motor
stopped.
–
Draw the lever (1) in your direction to loosen the screw fixing the
needle.
–
Remove the needle and insert a new one with the needle scarf (2)
to the right according to the section (3) or (4). The needle may not
be oriented according to the section (5).
–
Turn the lever (1) back to tighten the needle fixing screw.
Caution! Danger of breakage!
A false orientation of the needle may damage the hook point.