Omron E5ZN Operation Manual page 103

Hide thumbs Also See for E5ZN:
Table of Contents

Advertisement

Variable Area Map
Variable
Address
type
C1
0100
-
0101
0102
0103
2
0104
0105
0106
0107
0108
0109
010A
010B
010C
010D
010E
010F
0110
0111
0112
0113
0114
0115
0116
0117
0118
0119
88
ch
Setting data name
Operation/adjustment
protection
Initial setting/communica-
tion protection
Setting change protection 00000000H (0):
Set point
Alarm value 1
Upper limit alarm value 1 FFFFF831H to 0000270FH (-1,999 to 9,999)
Lower limit alarm value 1 FFFFF831H to 0000270FH (-1,999 to 9,999)
Alarm value 2
Upper limit alarm value 2 FFFFF831H to 0000270FH (-1,999 to 9,999)
Lower limit alarm value 2 FFFFF831H to 0000270FH (-1,999 to 9,999)
Alarm value 3
Manual manipulated vari-
able
Heater burnout detection 00000000H to 000001F4H (0.0 to 50.0)
Set point 0
Set point 1
Temperature input offset
value
Upper limit temperature
input offset value
Lower limit temperature
input offset value
Proportional band
Integral time
Derivative time
Cooling coefficient
Dead band
Manual reset value
Heating hysteresis
Cooling hysteresis
00000000H (0):
No restriction at the operation/adjustment
levels
00000001H (1):
Moving to adjustment level is disabled.
00000002H (2):
Only "PV" and "PV/SP" display and change
enabled.
00000003H (3):
Only "PV" and "PV/SP" display enabled.
00000000H (0):
Moving to initial level/communications setting
level enabled and moving to advanced func-
tion setting level displayed.
00000001H (1):
Moving to initial level/communications setting
level enabled and moving to advanced func-
tion setting level not displayed.
00000002H (2):
Moving to initial setting/communication set-
ting levels is disabled.
OFF (Setting changes using E5ZN-SDL
enabled.)
00000001H (1):
ON (Setting changes using E5ZN-SDL dis-
abled.)
Lower value of set point limit to upper value of set point limit
FFFFF831H to 0000270FH (-1,999 to 9,999)
FFFFF831H to 0000270FH (-1,999 to 9,999)
FFFFF831H to 0000270FH (-1,999 to 9,999)
Standard: FFFFFFCEH to 0000041AH (-5.0 to 105.0)
Heating/cooling: FFFFFBE6H to 0000041AH (-105.0 to 105.0)
Lower value of set point limit to upper value of set point limit
Lower value of set point limit to upper value of set point limit
FFFFF831H to 0000270FH (-199.9 to 999.9)
FFFFF831H to 0000270FH (-199.9 to 999.9)
FFFFF831H to 0000270FH (-199.9 to 999.9)
00000001H to 0000270FH (0.1 to 999.9)
00000000H to 00000F9FH (0 to 3999)
00000000H to 00000F9FH (0 to 3999)
00000001H to 0000270FH (0.01 to 99.99)
FFFFF831H to 0000270FH (-199.9 to 999.9)
00000000H to 000003E8H (0.0 to 100.0)
00000001H to 0000270FH (0.1 to 999.9)
00000001H to 0000270FH (0.1 to 999.9)
Section 5-10