Overtemperature Conditions - Cisco XR 12410 Installation Manual

Xr 12410 router
Hide thumbs Also See for XR 12410:
Table of Contents

Advertisement

Chapter 4
Troubleshooting the Installation

Overtemperature Conditions

OL-13832-01
For additional power supply troubleshooting information, see the
"Troubleshooting the Power Subsystem" section on page 4-5
The following console error message indicates that the system has detected an
overtemperature condition or out-of-tolerance power value inside the system:
Queued messages:
%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown
The preceding message could also indicate a faulty component or temperature
sensor. Enter the show environment command or the show environment all
command at the user EXEC prompt to display information about the internal
system environment. The information generated by these commands include:
Voltage measurements on each card from the DC-to-DC converter
The +5 VDC for the MBus module
The operating voltage for the blower module.
Temperature measurements received by two sensors on each card (one for
inlet air temperature and one for the card's hot-spot temperature), as well as
temperature measurements from sensors located in each power supply.
If an environmental shutdown results from an overtemperature or out-of-tolerance
condition, the Fault indicator on the power supply lights before the system shuts
down.
Although an overtemperature condition is unlikely at initial system startup, make
sure that:
Heated exhaust air from other equipment in the immediate environment is not
entering the chassis card cage vents.
You allow sufficient air flow by maintaining a minimum of 6 inches
(15.24 cm) of clearance at both the inlet and exhaust openings on the chassis
and the power modules to allow cool air to enter freely and hot air to be
expelled from the chassis.
Troubleshooting the Cooling Subsystem
Cisco XR 12410 Router Installation Guide
4-37