Chapter 3
Installing the Cisco XR 12410 Router
Connecting Power to an AC-Powered Router
Step 1
Step 2
OL-13832-01
Use the following procedure to connect the AC power cords to the router.
Connect each AC power supply to a dedicated power source (branch
Note
circuit). Each AC-input power supply operates between 200 and 240 VAC
and requires at least a 20 A service for North American use, or a 13 A
service for international use. For more information on AC power cords,
see the
"Power Connection Guidelines" section on page
Connect each power cable to the AC power connector on the horizontal trough and
secure them with their retention clips
Plug each power supply cable into its AC outlet.
Figure 3-30
Connecting Source AC to the AC-Input Power Connector
Connecting Power to the Router
(Figure
3-30).
Cisco XR 12410 Router Installation Guide
2-13.
3-45