Tp Cable Termination - Extron electronics TP Series User Manual

Twisted pair transmitter and receiver
Hide thumbs Also See for TP Series:
Table of Contents

Advertisement

tP Cable termination

NOtE: RJ-45 termination with cAt 5, cAt 5e, cAt 6, cAt 6e, and cat 7 cable must
Figure 9 lists the recommended termination of tP cables with RJ-45 connectors. terminate
both ends of the cable identically, in accordance with either the TIA/EIA T 568A or the
TIA/EIA T 568B wiring standard.
Figure 9.
NOTE:
NOtE: Do not use Extron UtP23SF-4 Enhanced Skew-Free
terminating shielded cable
NOtE: the transmitter and receiver pair work with unshielded twisted pair (UtP)
To terminate the STP cable:
1.
2.
comply with the tIA/EIA t 568A or tIA/EIA t 568B wiring standard for all
connections.
RJ-45
Pins:
Connector
1 2 3 4 5 6 7 8
Pin
568 A
1
White-green
2
Green
3
White-orange
4
Blue
5
White-blue
6
Orange
7
White-brown
Insert
8
Brown
Twisted
Pair Wires
TP Cable Termination
Terminate both ends of a cable identically, in
accordance with either the TIA/EIA T 568A or the
TIA/EIA T 568B wiring standard.
transmitter and receiver. Skew-free A/V cable was designed for most Extron tP
transmitter/receiver applications, but the USB Extender tx/Rx does not work
properly with this cable.
or shielded twisted pair (StP) cables; but to ensure Fcc class A and cE
compliance, StP cables are required.
Peel back the cable shielding (figure 10) from the end of the cable the length of the RJ-
45 connector body (approximately 7/8 inch [2.2 cm]) and fold it back.
Figure 10.
Peel Back the Cable Shielding
cut away and discard the clear cellophane inner wrapper from the end of the cable back
to the folded-over cable shielding.
568 B
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
Peel back shield and
fold back.
USB Extenders • Reference Information
A/V UtP cable to link the
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Usb extender txUsb extender rx