Tp Cable Termination - Extron electronics DTP DVI 301 User Manual

Dvi & hdmi twisted pair extender
Hide thumbs Also See for DTP DVI 301:
Table of Contents

Advertisement

TP cable termination

Figure 6 details the recommended termination of TP cables with RJ-45 connectors in
accordance with either the TIA/EIA T 568A or the TIA/EIA T 568B wiring standard.
Side
Pins:
1 2 3 4 5 6 7 8
Pin
1
2
3
4
5
6
Insert
7
Twisted
8
Pair Wires
Figure 6.
TP Cable Termination
NOTES:
RJ-45 termination with CAT 5e, CAT 6, or CAT 6a cable must comply with
the TIA/EIA T 568A or TIA/EIA T 568B wiring standard for all connections.
Terminate both ends of both cables identically, in accordance with either
TIA/EIA T 568A or TIA/EIA T 568B.
Do not use Extron UTP23SF-4 Enhanced Skew-Free™ AV UTP cable or
STP201 cable to link the transmitter and receiver. The DTP DVI 301 Tx/Rx
does not work properly with these cables.
Only one cable, DTP, is necessary. The Analog Audio cable carries an
additional audio signal that is not required for system operation.
Connect transmitter DTP Out to receiver DTP In.
Connect transmitter Analog Audio Out to receiver Analog Audio In.
If necessary, check the DTP Out to DTP In cable connection as follows:
1. Plug a cable into the DTP port on the powered unit.
2. Connect the opposite end of the cable into the DTP port on the
unpowered unit.
If the DTP Link LED and the Power LED on the unpowered unit are lit, the
connection is correct.
RJ-45
Connector
TIA/EIA T
TIA/EIA T
568 A
568 B
Wire color
Wire color
White-green
White-orange
Green
Orange
White-orange
White-green
Blue
Blue
White-blue
White-blue
Orange
Green
White-brown
White-brown
Brown
Brown
DTP DVI 301 • Installation and Operation