Canon imagePROGRAF iPF8400S User Manual page 798

Hide thumbs Also See for imagePROGRAF iPF8400S:
Table of Contents

Advertisement

Adjustment Types of Color Calibration
Even if paper categorized as Unique calibration is used, if the media type has yet to execute color calibration even once
and does not have any dedicated calibration adjustment values, the calibration adjustment values are overwritten when
Note
Common calibration is executed.
Calibration values configured by color calibration using the printer sensor and calibration values configured by color cali-
bration using the optional Spectrophotometer Unit are managed as separate data.
Because of this, the calibration values configured using the Spectrophotometer Unit are not overwritten when Common
calibration is executed using the printer sensor.
Checking the Applied Calibration Values
Depending on the paper type, it may be possible to execute color calibration using both the printer sensor and the
Spectrophotometer Unit and to have two sets of calibration values.
In this case, the calibration values that were set when color calibration was executed the last time are applied when
printing.
The currently applied calibration values can be checked using the Color Calibration Management Console or Control
Panel menu.
How to Check
Check in the Col-
or Calibration
Management
Console.
Check in the
menu of the Con-
trol Panel.
To Confirm the Paper Information Registered on the Printer
Refer to the Calibration sheet on the Color Calibration Management Console when checking details on the com-
puter.
(See "Calibration Sheet (Windows).")
(See "Calibration Sheet (Mac OS).")
To print media information, select Paper Details on the Control Panel menu.
The following is displayed in the Calibration field.
Display
Standard
High Precision
OK(Common)
OK(Unique)
N/A
N/A(Colorime-
798
try Only)
How to Operate
Display the Paper Status dialog box and view
the Type.
(See "Calibration Sheet (Win-
dows).")
P.812
(See "Calibration Sheet (Mac
OS).")
P.848
From Set./Adj. Menu, select Adjust Printer >
Calibration > Calibration Log and then view
Adjustment Type.
(See "Menu Settings.")
P.641
P.812
P.848
Supports color calibration using the printer sensor
Supports color calibration using the Spectrophotometer Unit
Executes Common calibration
Executes Unique calibration
Color calibration cannot be executed
Color calibration cannot be executed, but it can be used for acquiring color
measurement data
Auto Adjust: Calibration values set using the printer sensor
Auto Adjust (High Precision): Calibration values set using the Spec-
trophotometer Unit
Common Calibration: Calibration values set using the printer sensor
(Common calibration)
Unique Calibration: Calibration values set using the printer sensor
(Unique calibration)
UniqCal HiPrec/Std: Calibration values set using the Spectrophotom-
eter Unit (Pattern Size is Standard)
UniqCal HiPrec/Lge: Calibration values set using the Spectrophotom-
eter Unit (Pattern Size is Large)
Meaning
Displayed Content
iPF8400S
User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents