1. Installing the Copier
Installation Site
To ensure utmost safety and prevent possible malfunctions of the copier, install it in a location which
meets the following requirements.
A place away from a curtain or the like that may
catch fire and burn easily.
An area where there is no possibility of being
splashed with water or other types of liquid.
An area free from direct sunlight.
A place out of the direct air stream of an air
conditioner, heater, or ventilator.
A well-ventilated place.
A dry place.

Power Source

The power source voltage requirements are as follows.
Use a power source with little voltage fluctuation.
Voltage Fluctuation
Frequency Fluctuation

Space Requirements

To ensure easy copier operation, supply replacements and service maintenance, adhere to the
recommended space requirements detailed below.
* Be sure to allow a clearance of 150 mm or more at the back of the copier as there is a ventilation duct.
1,543
622
:
Within ± 10%
:
Within ± 0.3%
921
1,086
640
A dust-free location.
An area not subject to undue vibration.
A stable and level location.
A place where ammonia or other organic gas is
not generated.
A place which does not put the operator in the
direct stream of exhaust from the copier.
A place which is not near any kind of heating
device.
1,276
511
765
1154O026AA
Scale: mm