For example, suppose you create a calculated measure M1 with a Regular Timing
of Before Rollup. You then create calculated measure M2 with a Regular Timing
of After Rollup, and you reference M1 when defining M2. The rollup timings
conflict.
Procedure
To avoid this problem, ensure that the rollup timings specified for cross-referenced
calculated measures do not conflict.

TR2708

Regular measures measure_name1 and measure_name2 are referenced by the
calculated measure measure_name3, which has a rollup timing of 'Before Rollup'.
Therefore, both regular measures must be associated with the same data sources.
You have referenced two or more measures in a calculated measure that has a
rollup timing of Before Rollup, but at least one component of the calculated
measure is not available to provide the values for the calculation because the
measures come from different data sources.
Procedure
When referencing two or more measures in a calculated measure that has a rollup
timing of Before Rollup, ensure that the source data for your model is structured
so that all measures used in the Before Rollup calculated measure are contained in
the same data file.

TR2710

Level level_name has an allocation specified for measure measure_name1 using
measure measure_name2. The referenced measure must include a lower level in its
measure scope than the measure being allocated.
A measure that you have used to allocate another measure does not cover the
portion of the dimension map over which you are attempting to allocate values.
For example, you have tried to proportionally allocate values for measure A to
lower levels in a dimension using measure B. However, the domain for measure B
does not include the levels in which you are attempting to allocate measures.
Procedure
To avoid this problem, ensure that your allocation is based on a measure at the
appropriate level in the dimensional hierarchy.
Tip: You can use the Show Scope command to check the scope of an allocated
measure.

TR2711

There are no data sources set for category generation.
You have tried to either generate categories or create PowerCubes when no data
sources are set to be run as part of the process.
Appendix C. IBM Cognos Transformer Error Messages