Tr0128; Tr0131; Tr0132; Tr0133 - IBM Cognos User Manual

Version 10.1.1
Table of Contents

Advertisement

2. If you are using Cognos Transformer to generate a PowerCube on an HP-UX 10

TR0128

Only data source input files of the following types are supported in this mode
data_source_list.
You are using Cognos Transformer on a UNIX orLinux server but are not
specifying an accessible data source.
Procedure
To resolve the problem, specify a data source that your UNIX/Linux server can
access, and then rebuild your PowerCube or cube group.

TR0131

The argument for command line option -k is invalid.
When trying to pass database login information to Cognos Transformer using the
-k command line option, an invalid entry has been detected.
Procedure
To resolve the problem, ensure that you enter a valid value for the -k option. For
more information, see Appendix A, "Command Line Options," on page 209.

TR0132

The database name in the command line is blank.
When trying to pass database login information to Cognos Transformer using the
-k command line option, there is no database name provided.
Procedure
To resolve the problem, ensure that you enter a valid database name . For more
information, see Appendix A, "Command Line Options," on page 209.

TR0133

Unable to delete file file_name.
Cognos Transformer is unable to delete a model file.
Procedure
To resolve the problem, ensure that the file is not currently locked by another
process, and that it is not a read-only file.
252
IBM Cognos Transformer Version 10.1.1: User Guide
server computer, and the data source is an .iqd file that accesses a Sybase
database, ensure that the following requirements are met:
v Open Client must be installed on the HP-UX server computer.
v The Sybase and DSQuery environment variables must be set.
v The Sybase /bin directory must be in the path.