For example, suppose two data sources are used to generate categories for a
Products dimension that contains the levels Product Line, Product Brand, and Item.
If one data source contains values that generate categories down to the Item level,
and the other data source contains values that generate categories to only the
Product Brand level, then the dimension is unbalanced: leaf categories occur at
different levels in the dimension hierarchy.
Procedure
To avoid this problem, ensure that all data sources generate categories to the same
level in the dimension. Also, ensure that the timing for each data source in the
Data Sources list is set so that categories are generated using the appropriate data
sources.

TR2705

PowerCube cube_name does not contain any measures.
You have designed a Powercube that excludes all the measures referenced in the
model.
Procedure
To avoid this problem, on the property sheet for the PowerCube you are creating,
click the Measures tab and ensure that you have included at least one measure.

TR2706

Level level_name can't be reached in drill-down path drill_category_name for data
source data_source_name.
A level must either be the first source level, be directly below a source level, or be
designated as a unique level. All measures in data source data_source_name will
have zero values in the PowerCube.
The level that is identified in the error message is not accessible in the listed
drill-down path.
Procedure
To avoid this problem, ensure that all levels associated with columns in a data
source that do not contain their ancestor levels are unique. Also, ensure that any
identically-named columns exist in one or more other data sources, and that these
other data sources also include the columns that generate categories for the
ancestor levels.

TR2707

Measure measure_name1 is referenced by the calculated measure measure_name2.
These measures must have the same rollup timing.
You have specified calculated measures, one of which references the other, and
which have conflicting rollup timings.
300
IBM Cognos Transformer Version 10.1.1: User Guide