One of your source files may have been inadvertently overwritten by an empty
file, or the process that creates your source files may have failed and created a file
with no records.
Procedure
To resolve the problem, ensure that each source file associated with the data in
your model contains the correct data. You can confirm the name of the file
associated with a data source in the Source tab of the Data Source property sheet.

TR0111

file_name is not a valid file name.
You have specified an invalid file name for a PowerCube or a data file that is
related to a data source.
Procedure
To resolve the problem, check the name of the file you entered, and verify that it is
correct.

TR0112

There is not enough memory available.
There is insufficient memory for Cognos Transformer to perform some operation.

Solution for Windows

Procedure
Close as many open applications as possible. If this fails to correct the problem,
save your model, exit, and then restart Cognos Transformer. You may need to
restart Windows.
If this is a recurring problem, you may need to augment computer memory in
order to continue working on the model or PowerCube.

Solution for UNIX or Linux

Procedure
Try lowering the MaxTransactionNum setting. You may also need to increase the
memory setting on your data server. For information about optimizing UNIX or
Linux production environments, see Chapter 9, "Guidelines for Optimizing
Production Environments," on page 191.
Note: If you are working on an HP9000 computer, the problem may be the data
region setting. Try increasing the MAXDSIZkernel setting. For more information,
consult your HP9000 documentation.