Tr0701; Tr0702; Tr0705 - IBM Cognos User Manual

Version 10.1.1
Table of Contents

Advertisement

v if you set the Inclusion setting on the Category property sheet to either
v if you use the diagram to either suppress or exclude one of the categories that
For example, suppose that you create a cube group based on States in a States
dimension that contains levels State and Outlet. Assume that the State level
contains categories State01, State02, and State03, and that Cognos Transformer
creates three cubes within the cube group, one for each state. If you then create
and apply a dimension view that suppresses or excludes State01, the cube for
State01 will also be removed, unless you click No to prevent the deletion.
Procedure
To avoid disrupting your cube group structure, click No, then fix your model
design.

TR0701

A PowerCube was expected but not found. Either you have referred to a
PowerCube by an object name or object identifier that Cognos Transformer is
unable to locate, or you have not referenced the PowerCube.
This error occurs when MDL syntax requires an object and is unable to find it. In
this case, the object is a PowerCube.
The problem may be that the PowerCube was not referenced, or that it was
referenced with an incorrect object name or object identifier.
Procedure
You can verify Cognos Transformer object names and identifiers on the Windows
interface. To make them visible, select the Object name and Object identifier
check boxes on the Titles tab of the Preferences property sheet. The object name
and identifier will appear in the title bar at the top of each property sheet, and also
in a tool tip when your pointer hovers over an object.
You can also find object identifiers in the .mdl file. For more information, see the
Cognos Transformer Developer Guide.

TR0702

You cannot delete this PowerCube because it belongs to a cube group.
Cognos Transformer will not allow you to delete a cube that belongs to a cube
group.
Procedure
Instead of deleting the entire cube from the group, you can create a dimension
view that excludes the data associated with the category you want to remove.

TR0705

Category category_name has been excluded from Cube Group cube_group_name.
A PowerCube cannot be created in this cube group.
Suppress or Exclude for a category in the level that defines the cube group
defines a cube within a cube group
Appendix C. IBM Cognos Transformer Error Messages
271

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents