This error message may appear when you make updates to a model using an MDL
script. Under normal circumstances, the Cognos Transformer Windows interface
prevents you from including a measure that is excluded in an ancestor custom
view.
Procedure
1. Verify that the MDL script is correct, and that you have specified the correct
2. If the custom view for which you want to include the measure does require

TR0109

Cognos Transformer could not read the data source.
You have specified an invalid data source, or a file format that is not appropriate
for the type of data source defined in your model.
For example, this error may occur if you are using an .iqd file as a data source
with a 32-bit ODBC driver, and the driver setup specifies the wrong transaction
level. It may also occur if the required security information is lacking or the
tnsnames.ora file references an incorrect SQL *Net connection string.
Procedure
To resolve the problem, ensure that your source file is valid, and that it uses a
format that is appropriate for the type of data source defined in the model.
For example, if you are using an .iqd file with a 32-bit ODBC driver, try changing
the transaction level from Repeatable Read to Read Uncommitted, and enter a
user ID and password in the Client Access driver setup.

TR0110

No records were found in data source data_source_name; the file is empty.
You have tried to generate categories from an empty input file. The file exists, but
contains no records that Cognos Transformer can use.
object identifier for each of the objects referenced.
access to that measure, you can
v change the properties of the ancestor custom view in which the measure is
excluded
Note: If you use this option, all members of the subordinate custom view
(the one for which you are trying to include the measure) will gain access to
the measure.
v add specific users from the subordinate custom view (the one for which you
are trying to include the measure) to the ancestor custom view in which the
measure is included
However, this will give the users access to all information that is accessible
by the ancestor custom view.
v create a new custom view in which the measure is included, adding users to
it as required to meet your reporting needs
For more information, see Chapter 7, "Adding Security," on page 147.