Installing Battery Backup Units
router# show platform battery short
AC power supply ......... ON
Battery present ......... YES
Battery ready ........... YES
Number of battery units . 3
Time to empty ........... 12:29
Unit#
-----+-------------+------------
0
1
2
The command output displays backup battery summary information in short format (formatted for a
management device).
router# show platform battery sprom
Battery unit 0
SPROM:
Common block:
FRU Major Type
FRU Minor Type
OEM String
Product Number
Serial Number
Part Number
Part Revision
Mfg Deviation
H/W Version
Mfg Bits
Engineer Use
snmp OID
Power Consump
CLEI Code
VID
Battery specific block:
Vendor name
Vendor product number
Vendor revision number
Vendor sequence number
Date code
Build version
Output power max
Input power max
BBU chemistry
Cells in series
Firmware version
Firmware revision
Min discharge temp
Max discharge temp
Min charging temp
Max charging temp
Output current max
Output voltage max
Battery unit 1
SPROM:
Common block:
FRU Major Type
FRU Minor Type
OEM String
Product Number
OL-26223-04
Charge level
State
89 %
Idle
97 %
Full
90 %
Idle
: 0xAB05
: 0x0
: Cisco Systems, Inc.
: CGR-BATT-4AH
: NVT17244415
: 74-10147-02
: 01
:
: 6.0
: 0
: 0
: 1.9.12.3.1.9.91.12
: 0
:
: V00
: NVT
: 1132-20D802-1CB
: AAAA
: 7
: 06192013R6
: R6
: 40
: 20
: Li-ion
: 3
: 3
: 5213
: 0
: 253
: 333
: 273
: 323
: 400
: 0xAB05
: 0x0
: Cisco Systems, Inc.
: CGR-BATT-4AH