Exiting The Ssu; Fru/Sdr Load Utility; When To Run The Fru/Sdr Load Utility - HP Carrier-grade cc2300 Product Manual

Useræs guide and technical useræs guide - hp carrier grade server cc2300
Hide thumbs Also See for Carrier-grade cc2300:
Table of Contents

Advertisement

FRU Menu
The FRU menu has the following options:
Properties: Displays FRU information from the BMC. These fields are display only.
Reload: Reloads the FRU entries from the server.
Help
The Help menu has the following option:
Help Topics: Displays the help information for the FRU Manager Add-in.

Exiting the SSU

Exiting the SSU causes all windows to close.
Exit the SSU by opening the menu bar item File in the SSU Main window.
Click on Exit,
Or,
Highlight Exit, and press <Enter>.

FRU/SDR Load Utility

The Field Replacement Unit (FRU) and Sensor Data Record (SDR) Load Utility is a DOS-based
program used to update the server management subsystem's product level FRU, SDR, and the
SM BIOS (SMB) nonvolatile storage components (EEPROMs). The load utility
Discovers the product configuration based on instructions in a master configuration file
Updates the nonvolatile storage device (EEPROM) associated with the Baseboard Management
Controller (BMC) that holds the SDR and FRU area
Updates the SMB area located in the BIOS nonvolatile storage device
Generically handles FRU devices that may not be associated with the BMC

When to Run the FRU/SDR Load Utility

You should run the FRU/SDR Load Utility each time you upgrade hardware in your server,
excluding add-on PCI boards, hard drives, and RAM. For example, if a second microprocessor is
added, you need to run this utility. The utility will program the sensors that monitor the newly
added microprocessor.
Because the firmware must reload to properly initialize the sensors after programming, turn the
server off and unplug/disconnect the power cords from the server. Wait approximately 30 seconds,
and plug-in/reconnect the power cords.
54