Table 8. Led Indicators - HP Carrier-grade cc2300 Product Manual

Useræs guide and technical useræs guide - hp carrier grade server cc2300
Hide thumbs Also See for Carrier-grade cc2300:
Table of Contents

Advertisement

Introduction
The DC version of the cc2300 Carrier Grade Server uses a -48 to -60 VDC input switching power
subsystem, which provides up to 250 Watts with -48 to -60 VDC input and with current and remote
sense regulation.
Interface Requirements
DC Input
The DC power source may produce hazardous voltage levels exceeding -60 VDC and high energy
levels above 240VA that may cause electric shock or burns. All DC input connections should be
made only by a qualified service person only to prevent injury. All wiring terminals connected to
the DC input terminal block must be fully-insulated with no exposed bare metal.
DC Output Connectors
The power subsystem DC power and control signals are interfaced to the server system via wire
harnesses when the power supply modules are inserted into the power subsystem enclosure. The
safety ground pin of the power supply module is the first pin to connect and the last to disconnect
when the module is being inserted or removed from the power subsystem housing. In addition to
the 5 V Standby, -12 V, +3.3 V, +5 V and +12 VDC outputs, the following signals and output pins
are included:
+3.3 VDC remote sense
+5 VDC remote sense
+12 VDC remote sense
Remote sense return
Power Subsystem On (DC PWR enable)
Power Good
2
*
I
C
*
PS Failure, PS Presence, PS Predictive Fail, +12 V Mon, +5 V Mon, and the 5 V Standby rails
failure are being monitored via an I
Power Supply Module LED Indicators
There is a single bi-color LED to indicate power supply status. When DC is applied to the PSU and
standby voltages are available the LED blinks GREEN. The LED turns on GREEN to indicate that
all the power outputs are available. The LED turns on AMBER to indicate that the power supply
has failed, shutdown due to over current, shutdown due to over temperature, or is indicating a
predictive failure. Refer to LED Indicators for conditions of the LEDs. The Alert signal from the
Heceta-P will trigger an AMBER blinking LED condition. If the module condition is Alert and
Fail at the same time, the LED will be AMBER with no blinking. The LED is visible on the power
supply module's exterior surface at the back of the system.
Table 8.
LED Indicators
Power Supply Condition
No DC power to all PSU
No DC power to this PSU only
32
2
C interface chip.
Power Supply LED
OFF
AMBER
cc2300 Carrier Grade Server Product Guide